![NEC Aspila Topaz Скачать руководство пользователя страница 339](http://html.mh-extra.com/html/nec/aspila-topaz/aspila-topaz_programming-manual_248202339.webp)
331
Program 81:
Basic Hardware Setup for Trunk
81-01: Analogue Trunk Initial Data Setup
Programming Manual
IN
SA
SB
Description
Use
Program 81-01 : Analogue Trunk Initial Data Setup
to define the various basic timers for the Trunk
Interface of 308M/308ME cards.
Input Data
Prog. No.
Item
Input Data
Default
81-01-01
Companding method type
0 :
μ
-law
1 : A-law
1(A-law)
81-01-02
Loop Current Detection Time
1-255(8-2040ms)
75(600ms)
81-01-03
Clear Signal (Open Loop)Detection Time
1-255(8-2040ms)
37(296ms)
81-01-04
Ring Signal Detection Min. Time
1-255(8-2040ms)
13(104ms)
81-01-05
Single Ringing Detection Min. Time
0-255(0,8-2040ms)
82(656ms)
81-01-06
Double Ringing Detection Min. Off Time
0-255 (0,8-2040mS)
13 (104ms)
81-01-07
Double Ringing Detection Max. Off Time
0-255 (0,8-2040mS)
50 (400ms)
81-01-08
Ringing Signal Not Detection Minimum
1-255 (8-2040mS)
88 (704ms)
81-01-09
Time Ringing Signal Stop Detection Time
1-255 (64-16320mS)
47(3080ms)
81-01-10
Continuous Ringing Minimum Time
0-255 (0,8-2040mS)
38(304ms)
81-01-11
Continuous Ringing Maximum Time
0-255 (0,8-2040mS)
88(704ms)
81-01-12
AC Impedance Timer
1-255 (64-16320mS)
4 (256ms)
81-01-13
Grounding Time
1-255 (16-4080mS)
9 (144ms)
81-01-14
Flash (Hooking 1)
This sets the flash (Hooking 1) duration for
analogue trunk calls. See Program 14-02-04.
1-255 (16-4080mS)
50 (800ms)
81-01-15
Flash (Hooking 2)
This sets the flash (Hooking 2) duration for
analogue trunk calls. See Program 14-02-04.
1-255 (16-4080mS)
156(2496ms)
81-01-16
Pause Time
1-255(64-16320mS)
47(3008ms)
81-01-17
PFT Idle Detection Time
1-255(64-16320mS)
47(3008ms)
81-01-18
Grounding Start Time
1-255 (8-2040mS)
6 (48ms)
81-01-19
Grounding Start Give-up Time
1-255 (64-16320mS)
47 (3008ms)
81-01-20
Loop Reverse Detect Min. Time
1-255 (8-2040mS)
13 (104ms)
81-01-21
Loop Reverse Detect Max. Time
1-255 (8-2040mS)
107 (856ms)
81-01-22
Loop Disconnect Detect Min. Time
1-255 (8-2040mS)
63(504ms)
81-01-23
Loop Disconnect Detect Max. Time
1-255 (8-2040mS)
87(696ms)
81-01-24
On Hook Normal Detect Time
1-255 (8-2040mS)
3(24ms)
81-01-25
On Hook Reverse Detect Time
1-255 (8-2040mS)
2 (16ms)
81-01-26
On Hook Disconnect Detect Time
1-255 (16-4080mS)
188 (3008ms)
Содержание Aspila Topaz
Страница 1: ...Programming Manual Issue 1 0 Date July 2004 Intelligent Hybrid System ...
Страница 19: ...Introduction to Programming Before You Start Programming Programming Manual 11 For Your Notes ...
Страница 20: ...Introduction to Programming Before You Start Programming Programming Manual 12 For Your Notes ...
Страница 50: ...42 Programming Manual Program 10 System Configuration Setup For your Notes ...
Страница 84: ...76 Programming Manual Program 12 Night Mode Setup For your Notes ...
Страница 196: ...188 Programming Manual Program 21 Outgoing Call Setup For your Notes ...
Страница 262: ...254 Programming Manual Program 26 ARS Service Least Cost Routing For your Notes ...
Страница 286: ...278 Programming Manual Program 32 Door Box Setup For your Notes ...
Страница 326: ...318 Programming Manual Program 44 ARS F Route Setup For your Notes ...
Страница 338: ...330 Programming Manual Program 80 Basic Hardware Setup for System For your Notes ...
Страница 348: ...340 Programming Manual Program 81 Basic Hardware Setup for Trunk For your Notes ...
Страница 358: ...350 Programming Manual Program 82 Basic Hardware Setup for Extension For your Notes ...
Страница 389: ... For Your Notes ...