![background image](http://html.mh-extra.com/html/nec/1080xd/1080xd_user-manual_251085080.webp)
3-30
Service Processor
Table 3-31. EN Screen References (cont’d)
Reference
Description
C
When you press ENTER, the next page is displayed
D
Displays an alarm state for the DCDC converter on the CELLV Board/XIC/XBR Board
in the Main Chassis and Expansion Chassis.
If an alarm occurs, an asterisk (*) mark appears at the beginning of the line.
E
Displays an alarm state for the DCDC converter/fan/temperature of the PCIX Unit
and PCIV (Core Module).
If an alarm occurs, an asterisk (*) mark appears at the beginning of the line.
For information on the Fan Unit in the PCIV (Core Module), refer to B.
F
Displays the temperature detected by the board/unit temperature sensor.
If an alarm occurs, an asterisk (*) mark appears at the beginning of the line.
Also displays the threshold values hard-coded in iSPFW.
"FAN" indicates the threshold values for high-speed and low-speed fan rotation.
"IPMI" indicates the threshold values at which a report is sent to the software via the
IPMI interface.
" ACPI " indicates the threshold values at which a report is sent to the software via
the ACPI interface.
Содержание 1080Xd
Страница 1: ... U s e r s G u i d e EXPRESS5800 1080Xd ...
Страница 2: ......
Страница 4: ......
Страница 15: ...1 System Overview Overview System Features System Chassis System Functions Expansion Security ...
Страница 51: ...3 Service Processor SP Console OS Console Virtual SOP SP Command Console SP Command Reference ...
Страница 172: ......
Страница 189: ...6 Problem Solving Solving Simple Problems Troubleshooting the System ...
Страница 193: ...A Technical Specifications Main Chassis DVD ROM Drive Tape Drive FDD ...
Страница 198: ......
Страница 199: ...B Memory Upgrades Memory Configurations DIMM Installation ...
Страница 203: ...C Windows 2003 Installation Installing Microsoft Windows 2003 Creating a Mirrored Drive of Windows 2003 ...
Страница 210: ......
Страница 215: ...xx ...
Страница 216: ... 456 01683 001 ...