12-8 Chapter 12: Cash Drawer Interface
GP_LVL2—GPIO Level for Input or Output 2 Register
Offset Address: GP38h Attribute: R/W
Default Value: 00000FFFh Size: 32-bit
Lockable: No Power Well: See below
Bit Description
31:12
Always
0.
No
corresponding
GPIO.
11:0
GP_IO_SEL2[43:32]
—
R/W.
When
set
to
a
1,
the
corresponding
GPIO
signal
(if
enabled
in
the
GPIO_USE_SEL2
register)
is
programmed
as
an
input.
When
set
to
0,
the
GPIO
signal
is
programmed
as
an
output.
Bit Description
31:12 Reserved. Read-only 0
11:0
GP_LVL2[43:32]
—
R/W.
If
GPIO[n]
is
programmed
to
be
an
output
(via
the
corresponding
bit
in
the
GP_IO_SEL2
register),
then
the
corresponding
GP_LVL2[n]
bit
can
be
updated
by
software
to
drive
a
high
or
low
value
on
the
output
pin.
1
=
high,
0
=
low.
If
GPIO[n]
is
programmed
as
an
input,
then
the
corresponding
GP_LVL2
bit
reflects
the
state
of
the
input
signal
(1
=
high,
0
=
low).
Writes
will
have
no
effect.
Since
these
bits
correspond
to
GPIO
that
are
in
the
core
well,
these
bits
will
be
reset
by
PCIRST#.
Three
GPO
bits
and
one
GPI
bit
of
South
Bridge
ICH4
are
used
to
control
the
cash
drawer(s).
They
are
defined
below:
GPIO 32 CD_SW_AB
Input
1,
high
Drawer(s)
closed.
Input
0,
low
Drawer(s)
open.
GPIO 33 CD_SOL_A
Output
0,
low
turn
off
solenoid
A.
Output
1,
high
Activates
Solenoid
A.
GPIO 34 CD_SOL_B
Output
0,
low
turn
off
solenoid
B.
Output
1,
high
Activates
Solenoid
B.
Содержание RealPOS 70
Страница 1: ...NCR RealPOS 70 7402 Release 1 4 User Guide B005 0000 1463 Issue N ...
Страница 18: ...xvi ...
Страница 96: ...3 34 Chapter 3 Touch Screen Calibration Windows MT 7 12 ...
Страница 103: ...Chapter 4 Touch Screen Calibration Windows MT 5 64 SR4 4 7 8 Select Finish 9 Select Calibrate ...
Страница 119: ...Chapter 4 Touch Screen Calibration Windows MT 5 64 SR4 4 23 2 Select the Advanced button ...
Страница 122: ...4 26 Chapter 4 Touch Screen Calibration Windows MT 5 64 SR4 3 Select the Touchdown option 4 Select Close ...
Страница 124: ......
Страница 127: ...Chapter 5 Touch Screen Calibration Windows MT 5 64 SR6 5 3 6 Select Next at the Welcome screen ...
Страница 130: ...5 6 Chapter 5 Touch Screen Calibration Windows MT 5 64 SR6 10 Select Finish 11 Select Calibrate ...
Страница 146: ...5 22 Chapter 5 Touch Screen Calibration Windows MT 5 64 SR6 11 Select the Touchdown option 12 Select Close ...
Страница 148: ...5 24 Chapter 5 Touch Screen Calibration Windows MT 5 64 SR6 ...
Страница 152: ...6 4 Chapter 6 Touch Screen Calibration DOS ...
Страница 218: ...9 18 Chapter 9 Installing the Terminal in an Integrated Configuration ...
Страница 223: ...Chapter 10 2x20 Customer Display Interface 10 5 CP437 ...
Страница 224: ...10 6 Chapter 10 2x20 Customer Display Interface CP858 ...
Страница 225: ...Chapter 10 2x20 Customer Display Interface 10 7 CP866 ...
Страница 226: ...10 8 Chapter 10 2x20 Customer Display Interface CP932 ...
Страница 238: ...11 12 Chapter 11 APA Customer Display Interface 5X7 Character Table ...
Страница 239: ...Chapter 11 APA Customer Display Interface 11 13 10x14 Character Table ...
Страница 265: ...Chapter 12 Cash Drawer Interface 12 25 ReleaseMutex g_hHWPortMutex return result 7402 Modifications End Here end ...
Страница 268: ......
Страница 280: ...14 6 Chapter 14 Maintenance ...
Страница 288: ...16 4 Chapter 16 BIOS Updating Procedures ...
Страница 302: ...B 4 Appendix B Feature Kits ...