23. The EK0137 AC Mains cable has double-connectors at one end and a single connector at the
other end. Plug the single-connector end into the mains connection on the EZ0408 PSU Plate
assembly.
Fig. 6.23
–
Plug single end of EZ0137 to EZ0408 PSU Plate assembly
24. From Side A, unplug the mains connector from the relay board, which is located at the bottom of
the electrical enclosure (both narrow and wide bodies.) This is the same as the distribution board
from step 13 (a) of the disassembly.
- If doing Side A, that plug belongs to the pump.
- If doing Side B, that plug belongs to Side A.
Regardless, unplug it.