Chapter 5: Programming 5-45
RS232 Parameters 2
24041
BCC Options
A
Interface Control
B
Check Digit
C
0
Disable
1
Enable
0
None
1
ACK/NAK
2
XOn/XOff
3
ACK/NAK
&
XOn/XOff
0
Disable UPC-A
Disable EAN-8
Disable EAN-13
Disable UPC-E
1
Enable UPC-A
Enable EAN-8
Enable EAN-13
Disable UPC-E
2
Disable UPC-A
Disable EAN-8
Disable EAN-13
Enable UPC-E
3
Enable UPC-A
Enable EAN-8
Enable EAN-13
Enable UPC-E
Your Program
BCC Options
A
RS-232
Parameters - 2
2
1
Interface Control
B
Check Digit
C
4
Disable UPC-A
Disable EAN-8
Enable EAN-13
Disable UPC-E
5
Disable UPC-A
Disable EAN-8
Enable EAN-13
Enable UPC-E
6
Disable UPC-A
Enable EAN-8
Disable EAN-13
Disable UPC-E
7
Disable UPC-A
Enable EAN-8
Disable EAN-13
Enable UPC-E
8
Disable UPC-A
Enable EAN-8
Enable EAN-13
Disable UPC-E
9
Disable UPC-A
Enable EAN-8
Enable EAN-13
Enable UPC-E
A
Enable UPC-A
Disable EAN-8
Disable EAN-13
Disable UPC-E
B
Enable UPC-A
Disable EAN-8
Disable EAN-13
Enable UPC-E
C
Enable UPC-A
Disable EAN-8
Enable EAN-13
Disable UPC-E
D
Enable UPC-A
Disable EAN-8
Enable EAN-13
Enable UPC-E
E
Enable UPC-A
Enable EAN-8
Disable EAN-13
Disable UPC-E
F
Enable UPC-A
Enable EAN-8
Disable EAN-13
Enable UPC-E
The
RS232
Parameters
2
programming
mode
contains
some
of
the
parameters
required
for
RS232
communications.
From
this
mode
BCC
Options,
Interface
Control,
and
Check
Digit
can
be
selected.
Refer
to
the
“Parameter
Defaults”
section
earlier
in
this
chapter
for
the
factory
defined
default
value
of
each
programming
parameter.
BCC Options
The
BCC
Option
parameter
permits
the
use
of
BCC
at
the
end
of
a
message
to
be
enabled
or
disabled.
When
enabled,
the
BCC
is
the
last
character
sent
and
is
the
Exclusive
OR
of
each
byte
sent
prior
to
the
BCC,
except
the
prefix
byte.
Scan
the
Hex
0
tag
to
disable
the
BCC
Option,
or
scan
the
Hex
1
tag
to
enable
it.
Содержание 74 OFX (7874)
Страница 1: ...NCR RealScan 74 OFX 7874 Release 1 1 User Guide 25315 B005 0000 1822 Issue C...
Страница 16: ......
Страница 42: ......
Страница 81: ...Chapter 3 Installation 3 39 1 1 6 6 1 7 UPC Prefix Id 2 1 6 6 3 2 CR LF on 8 0 7 5 1 3 0 0 UPC Format...
Страница 240: ......
Страница 246: ......
Страница 247: ...Appendix A NCR Scanner Programming Tags Scanner Programming Tags BST0 2121 74 Release O 27064 Volume Adjustment 11817 A...
Страница 248: ...A 2 Appendix A NCR Scanner Programming Tags Reset 11818 Default R0046 Programming Mode R0042...
Страница 249: ...Appendix A NCR Scanner Programming Tags A 3 End R0043 Save and Reset R0044 Abort R0045...
Страница 252: ...A 6 Appendix A NCR Scanner Programming Tags Firmware Flashing Super ASIC Models 20600 Hex 0 R0048 Hex 1 R0049...
Страница 253: ...Appendix A NCR Scanner Programming Tags A 7 Hex 2 R0050 Hex 3 R0051 Hex 4 R0052...
Страница 254: ...A 8 Appendix A NCR Scanner Programming Tags Hex 5 R0053 Hex 6 R0054 Hex 7 R0055...
Страница 255: ...Appendix A NCR Scanner Programming Tags A 9 Hex 8 R0056 Hex 9 R0057 Hex A R0058...
Страница 256: ...A 10 Appendix A NCR Scanner Programming Tags Hex B R0059 Hex C R0060 Hex D R0061...
Страница 258: ......
Страница 264: ......
Страница 266: ......