Firmware
Version
5.2.9.8
29
5.2
SELT
–
Single
Ended
Line
Test
Purpose
of
Test:
A
SELT
test
is
performed
on
a
vacant
(non
‐
working),
and
open
pair
to
allow
qualification
of
the
pair
for
xDSL
service.
You
may
perform
a
SELT
test
from
a
cross
connect
point
or
frame
toward
the
customer
to
determine
if
a
spare
pair
will
support
the
xDSL
service
you
wish
to
provide.
Customer
equipment
may
be
on
loop,
however
DSL
equipment
should
be
removed.
DSL
equipment
will
absorb
any
test
signals
and
you
will
get
random
results.
You
may
also
perform
a
SELT
test
from
the
customer
NID
on
the
spare
pair
to
from
the
NID
back
toward
the
cross
connect
point.
Perform
the
following
steps
to
initiate
a
SELT
test
on
a
line
under
test.
Connect
the
test
leads
to
the
pair
under
test
and
the
ground
lead
to
a
good
ground.
Press
the
SELT
key.
You
now
select
the
location
you
are
testing
from,
options
are
Home
(customers
premise),
OSP
(outside
plant
cross
connect
point)
or
Port,
which
is
the
DSLAM
location.
Use
the
right
arrow
key
to
cycle
through
the
options;
press
OK
when
you
have
selected
the
correct
location
for
the
test.
It
is
important
to
select
the
correct
location;
different
parameters
may
be
used
in
different
locations
to
indicate
pass
or
fail
of
the
test
The
above
screen
shows
the
presence
or
absence
of
the
micro
‐
filter,
the
loop
length
and
whether
or
not
a
fault
was
detected
on
the
line.
Microfilter:
Pass
SELT Len:
751ft
SELT Fault:
none
[<
┘
Retest]
↓
SELT Test
Disconnect DSL equip
on line.