Firmware
Version
5.2.9.8
14
In
the
example
shown
below
the
line
status
was
an
OSP2
VER
CODE
and
by
depressing
the
Down
Arrow
Key
additional
information
is
provided
for
corrective
action.
NOTE:
The
creation
of
the
VER
CODE
shown
above
is
accomplished
by
analyzing
the
test
results
against
a
set
of
user
defined
thresholds
stored
in
the
unit.
The
results
of
this
analysis
process
generates
the
appropriate
VER
CODE
depending
on
whether
the
results
are
within
the
defined
thresholds
(Test
OK)
or
outside
the
thresholds
(Bad
Line)
4.
Performing
an
Automatic
Test
on
the
Subscriber
Line
–
DSLAM
EMULATION
An
automatic
test
on
the
subscriber’s
line
is
performed
upon
connecting
the
RJ11
test
clips
to
the
subscriber’s
line
and
powering
up
the
unit.
The
tests
performed
as
part
of
this
automatic
process
is
as
follows:
1.
DSL
Test
(4
Key)
2.
DELT
Test
(6
Key)
4.1
Automatic
Test
Process
Flow
To
perform
an
Automatic
Test
on
a
subscribers
line
perform
the
following
Steps.
Connect
the
test
clips
to
the
subscriber’s
line
to
be
tested.
NOTE
:
For
this
test
process,
connect
the
test
clips
looking
towards
the
Customer.
Power
up
the
NCI
465
unit
NOTE:
the
unit
will
first
go
through
a
boot
process
prior
to
executing
the
test
process.
Once
the
Boot
process
is
completed
the
number
4
key
on
the
unit
(DSL
Key)
will
begin
to
BLINK
indicating
the
test
process
has
begun.
Ver Code:
OSP2
Action:
High RFI noise.
Suspect bond/grounding
or flat drop wire
↓
Retest at NID to
determine if in-home
issue.
↑
Содержание NCI - 465 WMU