Optional Equipment:

 

The controller supports the following equipment. 

Aids in performing adjustments, cleaning, and knowledge. 

 

 

 

 
 

 

 

 

 

 

 

  
  

 

 

 

Smoke Temp. Sensor: 

Reads the current smoke 

temperature in the display. 

 

 

 

 

 

O

2

 Control Kit: 

Regulates the amount of 

oxygen in the flue gas. 

Regulates the quantity of 

wood pellet and air 

according to the desired 

O

2

%. 

 

Hot Water Priority Kit: 

Produces hot water only 

when it is needed. Closes 

hot water tank, when the 

house is heated. Kits 

available with either 2 or 3 

way motorized valve. 

 

Compressor Cleaning 

System: 

Cleans the burner 

head efficiently with high 

pressure. With this kit you 

need to use your own 

compressor. 

 

 

Compressor Cleaning L: 

Cleans the burner head 

efficiently with high 

pressure. “Low noise” 

compressor included. 

 

 

 

Solar Heating 

Use the pellet burner 

controller to run your solar 

system. 

 

External Temp. Sensor:

 

Stops burner through an 

external temperature sensor. 

 

 

 

 

 

Flow Sensor Kit: 

Reads the system flow in the 

display and calculates the 

current power consumption 

for the house. 

 

 

 

Distance Sensor for 

Hopper: 

Monitors the pellet level in  

a hopper and reports it in 

the controller.  

 

 

 

Exhaust Fan: 

Need greater chimney draft?  

The fan’s RPM can be 

synched with the burner's 

power output. Can be 

connected to the burner 

controller. 

 

Weather Compensation:  

Maintains a high boiler 

temperature while adjusting 

the house inlet temperature 

in relation to the outdoor 

temperature. 

 

 

Wireless thermostat: 

Stops the pellet burner with 

thermostat. 

Gives a smooth transition to 

summer time. 

Содержание V7

Страница 1: ...NBE PELLETS SYSTEM V7 V10 EN303 5 2012 Class 5 approved by DTI Approved for expansion vessel Energy class AA Manufacturer NBE Production A S Brinken 6 10 ster Vr Denmark www nbe dk...

Страница 2: ...scribed here in this manual It is recommended to study the menus prior to initial start Save this manual so you always have it available when needed Page 3 Comments on the Manual Page 4 Boiler Specifi...

Страница 3: ...indication of improper draft of the chimney all operation of your system must cease immediately and must remain so until a solution to the draft problem has been resolved Continuing operation may res...

Страница 4: ...ing Efficiency 93 3 93 4 94 7 91 4 EN Class 5 5 5 5 Output 10kW 14kW 24 kW 48kW 300 ELAB 1683 1700 1765 1859 Black Star BS20 BS30 BS30 BS40 Height mm 980 980 980 1084 Width mm 430 530 530 628 Depth mm...

Страница 5: ...4kW burner Up to 110kg day 60 watt hour Weight 12kg 30kW burner Up to 150kg day 80 watt hour Weight 15kg 40 60kW burner Up to 300kg day 150 watt hour Weight 30kg 80 120kW burner Up to 600kg day 200 wa...

Страница 6: ...stance to prevent temperatures from reaching an excess of 80 C This requirement applies even if the combustible material is covered with non flammable material If the distance is greater than 500 mm t...

Страница 7: ...oke in the hopper Warm drop shaft Smoke billows out of the fan or boiler during startup If you have any problems with your chimney it is a good idea to keep a diary of any draft problem as draft probl...

Страница 8: ...xcept oil for oil burners The floor must be kept free of spilled fuel dust and combustible waste as well as waste from other activities in the room Any burning embers must be extinguished with water a...

Страница 9: ...degrees Buildings with a roof slope that is less than 20 degrees and is adjacent to another building Buildings with a slope greater than 20 degrees Buildings with a slope greater than 20 degrees and h...

Страница 10: ...mall Heat for the house is supplied while hot water is being produced 3 DHW with 3 way valve Typically used when the water heater is large and when the surface coil is large The house is not supplied...

Страница 11: ...r must not be installed on combustible surfaces 3 Un insulated smoke pipe must not exceed 0 30 m long and must be provided with an access door 4 Chimney draft should be a min 5 PA and be stable Overpr...

Страница 12: ...tor on the burner 6 Install electricity for safety cut off thermostat according to the wiring diagram SAFETY THERMOSAT MUST ALWAYS BE FUNCTION TESTED The thermostat can be tested by using an electric...

Страница 13: ...tween C and C2 is interrupted and that the high limit safety thermostat is triggered To re activate the thermostat press hard on the red button marked B in the drawing You will also hear a click signa...

Страница 14: ...l Hopper Available in 4 different models 60x60cm 200L 140 kg 80x80cm 320L 220kg 80x140cm ext 500L 350kg 100x100cm 500L 350kg Fabric hopper Available in 3 different models with gate over the auger inle...

Страница 15: ...our vacuum transport Big bag Throw the mole in the bag Easy way to transport 1 ton Flat bottom hopper Is a top fed option that maximizes space by minimizing ceiling height requirements V bottom hopper...

Страница 16: ...may be factory installed wiring on the outputs L5 L10 L5 may be factory fitted for the moving grate L6 may be factory fitted for the compressor cleaning Remove these if there is a need for other equi...

Страница 17: ...output for equipment EKSTRA 3 PE N L9 Optional output for equipment EKSTRA 3 PE N L10 Optional output for equipment BUS GRD TX RX Expansion module ILT V1 V V2 O2 controller KONTAKT K K1 External ON O...

Страница 18: ...Cleaning L Cleans the burner head efficiently with high pressure Low noise compressor included Solar Heating Use the pellet burner controller to run your solar system External Temp Sensor Stops burne...

Страница 19: ...that the controller is online If you do not have the possibility of a direct cable connection these adapters picture on right can be used They can establish a connection to your router through your h...

Страница 20: ...will now have your own page with your own burner dashboard After a short period of time you should see data streaming from the burner Do you want data on your mobile phone Then download our App for t...

Страница 21: ...your graphs You will be contacted by E mail where we ask your permission to make changes NBE will assess your graphs and the burner reaction pattern and make adjustments based on the observations You...

Страница 22: ...le flame at 10 power 6 Once the burner is activated an ignition will be made After approx 20 minutes the burner will reach a nominal output 100 If necessary lock the burner output at 100 Now you can p...

Страница 23: ...surfaces inside the boiler must be brushed clean from any deposits and the ash can must be emptied When empting the ash can pay special attention to any build up of ash in the rear smoke chamber and f...

Страница 24: ...01 04 12 Kg 87 Empty ash container 1000 ON NEJ 01 12 13 19 Cleaning of semi cleaning 2000 ON NEJ 31 12 12 25 Cleaning under burning grate 1000 ON NEJ 31 12 12 50 Cleaning of fan 5000 ON NEJ 31 12 12 0...

Страница 25: ...grate is fitted wrong Mount it correctly Too high chimney draft Install a draft stabilizer in the chimney Set electric ignition power up Reduce the fan speed during ignition Stopped fan Check if the f...

Страница 26: ...ate with pipe insulation Too many electric ignitions Flow in the system is fluctuating Set the pressure controlled circulation pump to fixed pressure External thermostat unstable Set External wait up...

Страница 27: ...ir flow in the boiler and carries more moisture 1 more oxygen costs approx 0 5 in efficiency 10 Remove the retarder Turbolator Decreases resistance of the boiler and get a bad chimney to work better T...

Страница 28: ...de by agreement with NBE To the extent that NBE is liable to the purchaser NBE s liability is limited only to direct loss and not to damages incurred by connected equipment and or indirect damage loss...

Страница 29: ...CE Declaration of Conformity...

Отзывы: