Installation of the burner.
General Guidelines:
Installing the burner on the boiler:
1.
Check that the burner is not damaged during
transport.
2.
Check that the burning grate is inserted correctly
in the burner (see image right).
3.
Mount the burner and tighten the burner with the
2 wing nuts supplied. Never use locknuts, as the seal between the boiler
and the burner can leak over time.
4.
Make sure that the burner is horizontal and that all connections are tight.
5.
Mount the shield and the connector on the burner.
6.
Install electricity for safety cut-off thermostat according to the wiring diagram.
SAFETY THERMOSAT MUST ALWAYS BE FUNCTION TESTED!
The thermostat can be tested by using an electric kettle. The thermostat
must switch off when the temp. feeler is dipped into boiling water.
If necessary, adjust the switch-off temperature lower by
turning the screw inward.
Reset the thermostat by pressing hard on the red button!
External auger:
7.
Install the auger output over the burner.
8.
Auger should be at an angle between
0 and 50 degrees.
9.
The flexible hose should be angled enough as
to allow for the free passage of the wood pellets
to the burner without getting stuck in the PVC hose.
Содержание V7
Страница 29: ...CE Declaration of Conformity...