background image

Checking the LED display at the receiver R-18 and R-CAN:

(Optional with integrated charger)

The green LED flashes:

RADIO PRESENT. 
If the LED fails to come on:
1. Check that the transmitter is on.
2. Check the power supply of the receiver.
3. (Optional) Irregular flashing of the LED:
Check or change the current radio channel.

Checking the LED display at the receiver Compact-M:

(Without integrated charger)

The green LED flashes:

RADIO PRESENT. 
If the LED fails to come on:
1. Check that the transmitter is on.
2. Check the power supply of the receiver.
3. (Optional) Irregular flashing of the LED:
Check or change the current radio channel.

Service plug: 

For NBB service only.

Checking the LED's at the receiver PNN-BUS-3:

%

LED1: 

POWER ON. If LED fails to come on, check the power supply. 
If the power lead is OK, call in the after-sales service.

%

LED2: 

HF PRESENT. Steady light when transmitter is switched on
(insignificant for scanner operation).

%

LED3:

Flashes evenly during fault-free operation.
Irregular flashing means that the HF channel is probably at fault -
please set another channel.

%

LED4: 

If this LED comes on, the HF channel is at fault. 

%

LED5: 

Charge condition display of battery (only present when charger is 
integrated). Steady light when charging a battery. 
LED flashes: The battery is charged, the charging process is finished.

Checking the LED's at the receiver Compact-V:

%

LED 1 green: 

POWER ON. If LED fails to come on, check the power supply. 
If the power lead is OK, call in the after-sales service.

%

LED 2 yellow:

HF PRESENT. Steady light when transmitter is switched on
(insignificant for scanner operation).

%

LED 3 green:

Flashes evenly during fault-free operation.
Irregular flashing means that the HF channel is probably at 
fault - please set another channel.

%

LED 4 red: 

If this LED flashes, the HF channel is at fault (not in the 
scanner operation).
Steady light notifies the operator that an output function
is critical due to over current. 

®

MADE IN GERMANY

3.820.1008

®

ZULASSUNG  -  TYPE APPROVAL  -  AGREMENT -  HOMOLOGATION

I

SYSTEM

NON EU COUNTRIES

:

AUS
CDN

CH
CZ 
H
IS
KO

  

EU COUNTRIES

:

X

0560

no approval necessary  
2634 231 116A / 
2634 231 116 
BAKOM 95.0720.K.P
45251983
MÜ-40.039-083/96
IS-3236-00 
93335
NO96000433-R / 
NO95000545-R
  

1027/96
YK33-9806
K9VPOC90 T001 / 
K9VPNN3-5R001 /
O5RS-DE96AO 
3K43D/3R1B9/
SPLS/RX-439/98

PL 
TJY
USA

ZA

1

2

3

4

5

COMPACT-M

R-18

R-CAN

Receiver Type / Version:

Factory No.:

Frequency:

PNN-BUS-3

999 899 4990

400 -477 MHz

X

              

SERVICE PLUG

LED RADIO ON

LED RADIO ON

SERVICE PLUG

1 2 3 4

www.nbb.de

®

COMPACT-V

X

3.820.1195

LEDS

SERVICE PLUG

To maintain operational safety, a regular function check of the NBB radio remote control is 
necessary. In single-shift day-to-day operation, we recommend performing this check at 
least once a week. Checking is possible using the display lights provided on the receiver. 
To do so, the transmitter must be set to the ready-to-operate state. 
First connect just the receiver - the transmitter remains switched off.

%

Activate the transmitter by pressing the "STOP" key, resp. the key "START/ ON/ 
HORN".

%

Now check the commands (always start with the lowest stage) and check for cor-
rect function of the unit to be controlled.

%

Ensure in particular that there is nobody in the danger area. 

ACCIDENT RISK!

%

STOP

check

. Press the STOP key at the transmitter until the switch engages. 

Then observe if the unit to be controlled is switched off (time to switch off accor-
ding to the application).

6. FUNCTION CHECK

Содержание Nano-L SMJ

Страница 1: ...OPERATING INSTRUCTIONS Receiver Type Version Factory No Frequency Transmitter Type Version Factory No Frequency X X X Nano L SMJ USA Canada Compact M Compact M2 R 18 R CAN Receiver Compact V PNN BUS 3 ...

Страница 2: ...et terminal of the unit to be controlled The repair of the equipment must not be carried out other than by NBB or an NBB authorized tech nician Failure to observe these recommendations will put both you yourself and others at risk Under these circumstances NBB rescinds the guarantee and any other form of liability This radio control unit is designed exclusively for the control of construction mach...

Страница 3: ...with the STOP key and the ON HORN key The order you push the keys doesn t make any difference After you push the first key you have 5 seconds to push the second key A red dot flashes on the Planar NL Nano L display during operation Commands can now be put in by means of the controls To turn off the transmitter push the STOP key Option Turn the switch on the side to position ON When the letter L fl...

Страница 4: ...n Horn button 6 Release the On Horn button Troubleshooting If Jt couldn t be shown on the display please switch off the transmitter and repeat the teach mode activation procedure 2 3 1 2 4 1 5 3 3 2 3 1 2 4 1 5 3 6 Joystick teach mode activation with Piezo Before starting the joystick teach mode activation please switch off the transmitter 1 Push the Frequency change button and hold it 2 Push the ...

Страница 5: ...th plug GB 3 970 1452 and power supply 3 970 1448 100 240V AC 12V DC 2 253 1450 Universal charger 2 250 1449 12V 24V DC set with 2m cable black pluggable with plug Australia 3 970 1453 and power supply 3 970 1448 100 240V AC 12V DC 2 250 1450 Universal charger 2 250 1449 12V 24V DC set with 2m cable black pluggable with plug Europe 3 970 1449 and power supply 3 970 1448 100 240V AC 12V DC 2 250 14...

Страница 6: ...centrated energy source Never store a charged bat tery in a toolbox or similar where it could be short circuited by metal compo nents even a key in your trouser pocket can cause a short circuit Do not drop used up batteries into the domestic waste Hand over the batteries to collecti ve point By damages defects or premature wear caused by non observance of the above descri bed operating and safety ...

Страница 7: ...ing regulations If the NBB radio remote control is not used for a long period it is urgently recom mended if you use rechargeable batteries that they should be charged now and again about every 4 weeks This prevents deep discharges of the batteries and prolongs their useful life If you shut down the NBB radio remote control for a long period we recommend you take the batteries out of the transmitt...

Страница 8: ...ot previously been operated by radio control Failing this the receiver electronic circuit will not receive any power supply Ensure that the operating voltage of the receiver complies with the electrical specifi cations of the unit to be controlled The applicable operating voltage is specified in the supplement Never expose the receiver to a high pressure cleaning jet This applies to the transmitte...

Страница 9: ...es evenly during fault free operation Irregular flashing means that the HF channel is probably at fault please set another channel LED 4 red If this LED flashes the HF channel is at fault not in the scanner operation Steady light notifies the operator that an output function is critical due to over current MADE IN GERMANY 3 820 1008 ZULASSUNG TYPE APPROVAL AGREMENT HOMOLOGATION I SYSTEM NON EU COU...

Страница 10: ...material used Shipping costs shall be charged to the customer The warranty shall not cover wear and tear parts relays and batteries The function warranty shall be invalidated in the case of damage accident damage negligence incorrect use non compliance with ope rating conditions non compliance with operating testing and maintenance instructions and repairs or unit modifications not authorised by N...

Страница 11: ...the manufacturer could void the user s authority to operate the equipment The installer of this radio equipment must ensure that the antenna is located or pointed such that it does not emit RF field in excess of Health Canada limits for the general population consult Safety Code 6 obtainable from Health Canada s website www hcsc gc ca rpb This device complies with Industry Canada license exempt RS...

Страница 12: ...Compact V PNN BUS 3 Reception frequency range see rating plate Data security Generates a CRC code with a Hamming distance 4 Generates a neutral position 16 Addressing of each transmitter with its own unique combination max 2 possible combinations Security EMERGENCY STOP with self test max switching voltage 250V AC 12V 24V DC R 18 R CAN Compact M Compact V max switching current 4A AC 3A DC at 12V 2...

Страница 13: ...s GmbH Otto Hahn Straße 3 5 DE 75248 Ölbronn Dürrn Tel 0 72 37 9 99 0 Fax 0 72 37 9 99 1 99 eMail sales nbb de http www nbb de Technische und konstruktive Änderungen vorbehalten APPROVALS AND CERTIFICATES Approvals EU countries X X Enclosure EC Declaration of Conformity Obtainable at demand M Zert mbH Certificate DIN EN ISO 9001 2000 12 No 03022 ...

Отзывы: