Safety equipment in the NBB-radio remote control:

In the transmitter

, this comprises mainly:

%

STOP, resp. EMERGENCY STOP with disconnection of the power supply.

%

Automatic zero positioning.

In the receiver:

%

Automatic zero setting when switching back on after radio interruption.

%

Locking of the radio commands at relay level in the event of a defective STOP, resp. 
EMERGENCY STOP circuit.

To ensure fault-free operation, please follow precisely the following rules for operation: 
The unit to be controlled can only be switched on - it is assumed that the transmitter is 
ready to operate - when no command unit is actuated. The command necessary to do so 
is triggered by the key "ON/HORN". This triggers a horn signal in the unit to be controlled. 
After switch-on of the facility to be controlled, this key is used for repeated emission of the 
horn signal in accordance with working regulations.

If the NBB radio remote control is not used for a long period, it is urgently recom-
mended - if you use rechargeable batteries - that they should be charged now 
and again (about every 4 weeks). This prevents deep discharges of the batteries 
and prolongs their useful life. If you shut down the NBB radio remote control for a 
long period, we recommend you take the batteries out of the transmitter.

Frequency change: 

To change the frequency, keep the "ON/HORN" key pressed down. T h e n  o p e r a t e  t h e  
“FREQUENCY CHANGE" key. If the receiver locks into the new frequency, a horn signal is 
given (if present) and the unit to be controlled is ready for operation. 
Please observe the particular postal approval regulations of the concerned country.

Channel number:

 When changing the frequency the channel number lights up shortly in 

the display. During operation the choosen channel can be shown by pressing the 
“FREQUENCY CHANGE” key.
(See example on the left)

4. OPERATING THE UNIT

FREQUENCY CHANGE

O

N

/

H

O

R

N

F

R

E

Q

U

E

N

C

Y

C

H

A

N

G

E

O

N

/

H

O

R

N

F

R

E

Q

U

E

N

C

Y

C

H

A

N

G

E

FREQUENCY CHANGE

Содержание Nano-L SMJ

Страница 1: ...OPERATING INSTRUCTIONS Receiver Type Version Factory No Frequency Transmitter Type Version Factory No Frequency X X X Nano L SMJ USA Canada Compact M Compact M2 R 18 R CAN Receiver Compact V PNN BUS 3 ...

Страница 2: ...et terminal of the unit to be controlled The repair of the equipment must not be carried out other than by NBB or an NBB authorized tech nician Failure to observe these recommendations will put both you yourself and others at risk Under these circumstances NBB rescinds the guarantee and any other form of liability This radio control unit is designed exclusively for the control of construction mach...

Страница 3: ...with the STOP key and the ON HORN key The order you push the keys doesn t make any difference After you push the first key you have 5 seconds to push the second key A red dot flashes on the Planar NL Nano L display during operation Commands can now be put in by means of the controls To turn off the transmitter push the STOP key Option Turn the switch on the side to position ON When the letter L fl...

Страница 4: ...n Horn button 6 Release the On Horn button Troubleshooting If Jt couldn t be shown on the display please switch off the transmitter and repeat the teach mode activation procedure 2 3 1 2 4 1 5 3 3 2 3 1 2 4 1 5 3 6 Joystick teach mode activation with Piezo Before starting the joystick teach mode activation please switch off the transmitter 1 Push the Frequency change button and hold it 2 Push the ...

Страница 5: ...th plug GB 3 970 1452 and power supply 3 970 1448 100 240V AC 12V DC 2 253 1450 Universal charger 2 250 1449 12V 24V DC set with 2m cable black pluggable with plug Australia 3 970 1453 and power supply 3 970 1448 100 240V AC 12V DC 2 250 1450 Universal charger 2 250 1449 12V 24V DC set with 2m cable black pluggable with plug Europe 3 970 1449 and power supply 3 970 1448 100 240V AC 12V DC 2 250 14...

Страница 6: ...centrated energy source Never store a charged bat tery in a toolbox or similar where it could be short circuited by metal compo nents even a key in your trouser pocket can cause a short circuit Do not drop used up batteries into the domestic waste Hand over the batteries to collecti ve point By damages defects or premature wear caused by non observance of the above descri bed operating and safety ...

Страница 7: ...ing regulations If the NBB radio remote control is not used for a long period it is urgently recom mended if you use rechargeable batteries that they should be charged now and again about every 4 weeks This prevents deep discharges of the batteries and prolongs their useful life If you shut down the NBB radio remote control for a long period we recommend you take the batteries out of the transmitt...

Страница 8: ...ot previously been operated by radio control Failing this the receiver electronic circuit will not receive any power supply Ensure that the operating voltage of the receiver complies with the electrical specifi cations of the unit to be controlled The applicable operating voltage is specified in the supplement Never expose the receiver to a high pressure cleaning jet This applies to the transmitte...

Страница 9: ...es evenly during fault free operation Irregular flashing means that the HF channel is probably at fault please set another channel LED 4 red If this LED flashes the HF channel is at fault not in the scanner operation Steady light notifies the operator that an output function is critical due to over current MADE IN GERMANY 3 820 1008 ZULASSUNG TYPE APPROVAL AGREMENT HOMOLOGATION I SYSTEM NON EU COU...

Страница 10: ...material used Shipping costs shall be charged to the customer The warranty shall not cover wear and tear parts relays and batteries The function warranty shall be invalidated in the case of damage accident damage negligence incorrect use non compliance with ope rating conditions non compliance with operating testing and maintenance instructions and repairs or unit modifications not authorised by N...

Страница 11: ...the manufacturer could void the user s authority to operate the equipment The installer of this radio equipment must ensure that the antenna is located or pointed such that it does not emit RF field in excess of Health Canada limits for the general population consult Safety Code 6 obtainable from Health Canada s website www hcsc gc ca rpb This device complies with Industry Canada license exempt RS...

Страница 12: ...Compact V PNN BUS 3 Reception frequency range see rating plate Data security Generates a CRC code with a Hamming distance 4 Generates a neutral position 16 Addressing of each transmitter with its own unique combination max 2 possible combinations Security EMERGENCY STOP with self test max switching voltage 250V AC 12V 24V DC R 18 R CAN Compact M Compact V max switching current 4A AC 3A DC at 12V 2...

Страница 13: ...s GmbH Otto Hahn Straße 3 5 DE 75248 Ölbronn Dürrn Tel 0 72 37 9 99 0 Fax 0 72 37 9 99 1 99 eMail sales nbb de http www nbb de Technische und konstruktive Änderungen vorbehalten APPROVALS AND CERTIFICATES Approvals EU countries X X Enclosure EC Declaration of Conformity Obtainable at demand M Zert mbH Certificate DIN EN ISO 9001 2000 12 No 03022 ...