Gas -Oriental GB – Gas Teppanyaki Jumbo Grill
FRM-PDE-03-04
Table 9
Gas Type
Gas Pressure (mbar)
Normal
Minimum
Maximum
Natural gas H G20
20
17
25
LPG G30/G31
28 / 37
20/25
35/45
Gas Conversion
1.
Only professional and qualified mechanic can do this job.
2.
By looking “Adjustment”, replace Main Burner Injectors, Pilot Burner Injectors, and adjust correctly
Primary Air Setting for each Main Burner.
3.
Spare injectors are available with the appliance.
4.
Make sure the diameter printed on each injector in 1/100 of a millimeter.
5.
Convert the appliance after turn the gas OFF and in UP position and let Gas Teppanyaki Jumbo
Grill cool.
C = Inlet pressure point
D = Gas pipe
E = Flexible pipe
G = Inlet gas connection
M =
Manometer
R = Gas tap
Important! On completion of the operation, make sure that there are no gas leaks or
malfunctions
Fig. 10
NAYATI
23
20150917