Gas -Oriental GB – Gas Teppanyaki Jumbo Grill
FRM-PDE-03-04
Adjustment
•
Adjusting Small Combustion (Fig.11)
For Combi Wok Burner (Soup Burner), the small combustion must be adjusted into 4.5 kW for
Natural Gas. The pressures for the small combustion are 50 mbar and 30 mbar. To adjust the
Natural gas, follow direction below:
a. Operate burner in small combustion.
b. Turn OFF the security control knob handle.
c. Adjust small combustion nozzle (9) for 4kW. Turn clockwise to reduce warmth load, turn
anticlockwise to increase warmth load. Adjust the warmth load according to volume
method.
d. Ignites properly.
e. To change small combustion nozzle (9) for Liquid gas / LPG Gas, turn slightly against the
stroke.
•
Adjusting Pilot Flame (Fig 12) and (Fig 13)
Adjust the Pilot flame by using Natural gas only. Follow direction below:
a. Remove screw cover (10) and washer (11).
b. Adjust nozzle (C) to make Main Burner ignite properly. Turn the nozzle clockwise to reduce
gas flow. Turn anticlockwise to increase gas flow.
c. When operated with Liquid gas, turn nozzle (C) clockwise toward stroke. After adjusting
washer (11) and tightening cover screw (10).
Fig. 11
Fig. 12
Fig. 13
NAYATI
24
20150917