background image

DELTA HEAT POWER BURNER

INSTALLATION, USE,  & CARE MANUAL

P/N: 17628A 08/20

MODELS:

DHPW22

Summary of Contents for DHPW22

Page 1: ...DELTA HEAT POWER BURNER INSTALLATION USE CARE MANUAL P N 17628A 08 20 MODELS DHPW22 ...

Page 2: ......

Page 3: ...ny oth er appliance AVERTISSEMENT 1 Ne pas entreposer ni utilizer de l essence ni d autres vapuers ou liquids inflammables dans le voisinage de l appareil ni de tout autre appareil 2 Une bouteille de propane qui n est pas rac cordée en vue de son untilisation ne doit pas être entrpossée dans le voisinage de cet appareil ou de tout autre appareil THIS GRILL IS FOR OUTDOOR USE ONLY If stored indoors...

Page 4: ...refer to them when contacting the company or an authorized service agent This information is found on the data nameplate located on the bottom right side of the body near the regulator Remove the drip tray to visually access the nameplate from the front of the Power Burner MODEL ____________________________________________ SERIAL ____________________________________________ DATE OF PURCHASE ______...

Page 5: ... operating the power burner in a windy area Never use the Power Burner without the drip pan installed and push all the way to the back of the Power Burner Without the drip pan hot liquid and debris could leak downward and produce a fire hazard The pressure regulator supplied with the Delta Heat Gas Power Burner must be used Replacement pres sure regulators must be those specified by Delta Heat In ...

Page 6: ...STALLATION 5 LEAK TEST 6 ELECTRICAL REQUIREMENT 7 8 WIRING DIAGRAM 9 BURNER FLAME AIR SHUTTER ADJUSTMENT 10 POWER BURNER CUT OUT DIMENSIONS 11 INSULATION JACKET 12 OPERATING INSTRUCTIONS 13 CLEANING MAINTENANCE 14 15 EXPLODED VIEW 16 REPLACEMENT PARTS LIST 17 TROUBLE SHOOTING GUIDE 18 WARRANTY 19 HOW TO OBTAIN SERVICE 21 ...

Page 7: ... are included 3 Fill out the Warranty Registration Card and mail it to the indicated address POWER BURNER ACCESSORIES DHPW22 N DHPW22 L GRATE ROUND STAINLESS STEEL 1 1 GRATE ROUND MIDDLE STAINLESS STEEL 1 1 REGULATOR NG NG POWER BURNER ONLY PRE INSTALLED REGULATOR LP LP POWER BURNER ONLY PRE INSTALLED SPECIFICATIONS VALUE COUNTER OPENING HEIGHT 11 50 COUNTER OPENING WIDTH 19 50 COUNTER OPENING DEP...

Page 8: ...UCTION A minimum clearance of 12 from the sides and 12 from the back of the Power Burner to adja cent vertical combustible construction must be maintained DÉGAGEMENT DE TOUTE CONSTRUCTION COMBUSTIBLE Il faut maintenir une distance minimum de 12 po 30 48 cm sur les côtés et de 12 po 30 48 cm sur l arrière du gril par rapport aux constructions combustibles verticales adjacentes CLEARANCE TO NONCOMBU...

Page 9: ...R POWER SUPPLY CORD DOES NOT COME IN CONTACT WITH ANY HOT SURFACE OF THE POWER BURNER NEVER CONNECT THE POWER BURNER TO AN UNREGULATED GAS SUPPLY L P GAS SAFETY REQUIREMENT The LP gas supply cylinder must be constructed and marked in accordance with the Specifications for LP gas Cylinders of the U S Department of Transportation D O T or the National Standards of Canada CAN CSA B339 Cylinders Spher...

Page 10: ...osed exterior side of the enclosure located within 5 in 127 mm of the top of the enclosure and unobstructed The opening s shall have a total free area of not less than 1 in lb 14 2 cm kg of stored fuel capacity ii at least one ventilation opening shall be provided on the exposed exterior side of the enclo sure 1 in 25 4 mm or less from the floor and shall have a total free area of not less than 1 ...

Page 11: ...conversion plastic pin attached to the cap to the underside of the cap If the disc 1 2 in diameter of the pin is close to the cap then the regulator is set for Natural Gas If the disc is at the tip of the pin away from the brass cap the regulator is set for system LP application To convert to Natural Gas remove the plastic conversion pin and invert and replace it back in a man ner such that the di...

Page 12: ... supplied hose and regulator must be used Use only replace ment regulator and hose assemblies specified by DELTA HEAT LEAK TEST 1 Prepare a leak testing solution of sudsy water by mixing in a spray bottle with half liquid soap and half water 2 Confirm that all control knobs are in the OFF position 3 Turn the main gas valve supply ON 4 Apply leak testing solution by spraying on the pipe joints fitt...

Page 13: ...n the transformer s power cord to the properly grounded GFCI 120V outlet d A side burner plug to provide electrical power for side burner is located at the right rear of the front panel Fig 3 WARNING Electrical Grounding Instructions This outdoor gas cooking appliance is equipped with a three prong grounding plug for your protection against shock hazard and should be plugged directly into a proper...

Page 14: ...amaged in any manner Contact the manufacturer for repair 4 Do not let cord hang over the edge or touch hot surfaces 5 Do not us an outdoor cooking gas appliance for purposes other than intended 6 When connecting first connect plug to the outdoor cooking gas appliance then plug appliance into outlet 7 Use only Ground Fault Interrupter GFI protected circuit with this outdoor cooking gas appli ance 8...

Page 15: ...Delta Heat Service 562 263 3600 9 WIRING DIAGRAM LED LIGHT LED LIGHT ...

Page 16: ...amount of air is controlled by a sheet metal cup at the inlet of the burner called an air shutter It is locked in place by a set screw which must be loos ened prior to lighting the burner for adjustment The air shutter adjustment screws are accessible with a phillips screwdriver Loosen the lock screw of the air shutter Adjust according to the following directions Be careful as the burner may be ve...

Page 17: ...ENSIONS THESE DIMENSIONS ARE FOR NON COMBUSTIBLE CONSTRUCTION ONLY FOR COMBUSTIBLE CONSTRUCTION SEE NEXT PAGE NOTE It is recommended to build the enclosure for the Power Burner 6 12 LOWER than the countertop 11 50 19 50 20 75 24 26 22 22 31 20 75 WIDTH OF UNIT ...

Page 18: ...e construction If the Power Burner is to be placed into combustible enclosure an approved insulating jacket is necessary to prevent fire proper ty damage and bodily injury Use only Delta Heat DHIJ22 insulating jacket IMPORTANT If using LP gas cylinder and insulation jacket DHIJ22 use stainless flexible hose to connect LP gas cylinder to grill regulator ...

Page 19: ...ting Refer to spiders and insects warning and procedure under the cleaning and maintenance page of this manual TO LIGHT THE POWER BURNER S BURNER 1 Open the gas supply shut off valve 2 Push in the knob and verify that the igniter sparks If the igniter does not spark replace the 9V battery Reference page 7 for electrical requirements 3 Once sparking is verified simultaneously push in and turn the k...

Page 20: ...eriods of time However the conditions outlined above along with neglect can lead to surface corrosion or rust ATTENTION Do not allow food particles or grease to be left on the surfaces of the Power Burner These can attract rodents which are unsanitary and are likely to cause physical damage by chewing on the wiring which can cause permanent damage to the electrical components Specks of grease can ...

Page 21: ...lide the pan out and wipe it clean Make sure the drip pan is fully inserted back into the Power Burner It is highly recommended to clean the pan after every use to avoid any possibility of a grease fire DO NOT use the Power Burner without the drip pan pushed all the way to the back of the Power Burner unit SPIDER AND INSECT WARNING Spiders and other insects can nest in the burners and orifices of ...

Page 22: ...16 www deltaheat com EXPLODED VIEW ...

Page 23: ...W 375 CC X 125 FIP 2 17 S23216Y IGNITION BRACKET ASSEMBLY 1 18 S16323 IGNITION MODULE 1 19 S13199 BEZEL 2 20 S14156 SCREW 6 32 X 375 4 21 S13195 DELTA KNOB 2 22 S16272 BATTERY PACK 1 23 S14102 6 32 X 500 SCREW 2 24 S13201 DELTA HEAT EMBLEM 1 25 S16196 12V SWITCH 1 26 S14420 ROLLER BEARING 4 27 S14175 10 24 X 750 FLAT HEAD SCREW 4 28 S13891WY ROUND GRATE 1 29 S13892 ROUND GRATE MIDDLE 1 30 S13117 C...

Page 24: ...heck the air shutter for proper adjustment 3 Check any source of gas leak Low heat generated with knob in HI position 1 Check if the problem is isolated to only one burner If it appears so clean the orifice and burner clearing ports of any obstruction 2 Check for any bent or kinked fuel hose 3 Check if the air shutter is properly adjusted 4 Check for proper gas supply and pressure 5 Pre heat Power...

Page 25: ...loration surface scratches weather and atmospheric related staining and minor surface rust and oxidation which are normal conditions and are to be expected with any outdoor product This warranty does not apply to damages resulting from negligence alteration misuse abuse accident natural disaster loss of electrical power to the product for any reason improper installation or improper operation unau...

Page 26: ...20 www deltaheat com ...

Page 27: ...03 Visit us at www deltaheat com Please provide Model number Serial Number Date of purchase A description of the problem This Warranty Registration card must be returned within thirty days of purchased to properly activate your warranty This information is for our internal use only Or you may register online at http www deltaheat com CUSTOMER NAME MODEL ADDRESS SERIAL CITY STATE DATE PURCHASED ZIP...

Page 28: ...Customer Service ATTN Warranty Department 13259 166th Street Cerritos CA 90703 Service Direct Line 562 263 3600 Fax 562 801 3391 PLACE POSTAGE HERE CUT HERE ...

Reviews: