▶ Replacement of Thermometer (p 28, K401 T08, K402 T08-2)
① Temperature goes up and down greatly.
(It could happen after data input is adjusted)
☞ Contact「NAWON」
② The numbers on LCD change quickly.
③ Temperature doesn’t go up even though no problem is observed
in nozzle heater sensor and heater.
④ Thermometer LCD doesn’t turn on.
⑤ Check if thermometer’s switch operation terminal (T1) No. 23
and 24 are properly connected by a tester.
▶ A heater keeps breaking down.
① Replace TPR 501 unit with new one
② Clean nozzle (see page 13 and 21)
Nozzle wind from the left and right is not stable.
Check if the nozzle wind is okay.
③ If work area is humid, the moisture in filter and compressor should often
be removed.
☆ Air dryer needs to be installed
④ Check if pressure safety SW (PS220) properly operates
If nozzle pressure is less than 0.8kg/cm2, check there is any noise
in a machine room.
⑤ Check heater cable and connection
▶ Replacement of Solenoid
① Knife, upper roller, nozzle, and tape feed do not move.
② Check PCB (CN6) LED (D2. V. ROLLER / D5. NOZZLE / D6. T-FEED
/ D16. KNIFE) is properly displayed.
Check LED turns on when foot board is stepped on.
③ Check if voltage is confirmed in PCB connector (CN1, CN5)
No. (S01 V. ROLLER / S02 NOZZLE / S03 T-FEED / S04 KNIFE)
by a tester (220V).