ANTENNA CONNECTION

 

Connect the included antenna to the SMA connector of the display unit only when the power supply is switched OFF. 
 

RANGE 

 

Connection between the sensor and display unit works on a free 868 MHz band. The range is up to 1000 meters when the sensor 
transmitter or antenna is mounted on elevated position with no obstacle between the sensor and the display unit antenna. Inside 
buildings the range is much smaller. Normally the signal can be received through two to three walls. 
When sensor is located in dug-in tank, please mount the sensor antenna above ground for optimal performance. 
Additional range extending equipment like signal repeaters and auxiliary antennas can be purchased separately. 
 

DISPLAY

 

Switching between pages: 
With short presses of the SET button you switch between single tank display for each active tank, sensor address must be set for tank 
to become active, or display all 4 tanks at once. 
With the short presses of the HIST button you can view history charts for 24 hour, 7 days, 30 days and 1 year of selected tank. 
Please note: to change tank press SET button shortly to return to main display and using SET button select active tank. 
 

 

 

 

 

 

 

 
 

 

1. Status bar

 

 

 

2. Graphical display of level in tank

 

 

 

3. Current level in tank

 

 
 
 

 

 

 

Figure 4. (main display page) 

 

 

  

  

 

Figure 5.

 

(other display pages)

 

 

Description of main display for each tank: 

Status bar: 

 

Hi 

– High alarm: value in % or “Off”, if setting is not set 

 

Lo 

– Low alarm: value in % or “Off”, if setting is not set 

 

Crossed bell icon 

– Icon is shown when sound alarm is muted 

 

SD 

– icon is shown if SD card is inserted and working properly (only on LW410XL/D model)  

 

WiFi 

– icon is shown when WiFi connection is established, blinks when display unit transmits data to LiveData portal (only 

on LW410XW/D and LW410XL/D models) 

 

5 bars 

– 5 bars represent signal strength, 0 bar is lowest, 5 highest 

 

Signal reception icon - blinks, whenever data is received from sensor 

 

Temperature 

– if sensor supports temperature measurement, temperature is displayed in selected unit 

 

Empty battery icon 

– Icon is shown when sensor battery is running low and needs replacement 

Graphical display of level in tank: 

 

Tank number 1 to 4 

 

Rectangle is shown for rectangular or custom tank shape, circle is shown for round tank 

 

Arrows indicate position of high and low alarm if set in settings 

Current level in tank: 

 

Absolute level value in selected unit 

 

Percentage of level 

Description of display showing all four tanks at once 
Four tanks are shown on the display, tanks with no connected sensor are empty and contain no other information 

Status bar: 

 

5 bars above each tank 

– signal strength indicator where 0 bar is lowest, 5 highest 

 

Signal reception icon 

– blinks whenever data is received from any of the four sensors 

 

Crossed bell icon 

– Icon is shown when sound alarm is muted 

Graphical display of level in tanks: 

 

All tanks are shown as rectangles. Filled section represents level in each tank 

 

Arrows indicate position of high and low alarm if set in settings 

 

Description of history charts: 

Each column represents average level in tank in percentage between 0% (E 

– empty) and 100% (F – full)  

 

24-hour history: each column represents 12 minutes 

 

7-day history: each column represents 6 hours 

 

30-day history: each column represents 24 hours 

2         3

 

   

Содержание LW410

Страница 1: ...play unit can be mounted onto the ferrous surface with four mounting magnets optional accessories or with mounting screws not included to any flat surface Mounting the display unit with screws Unscrew...

Страница 2: ...muted SD icon is shown if SD card is inserted and working properly only on LW410XL D model WiFi icon is shown when WiFi connection is established blinks when display unit transmits data to LiveData po...

Страница 3: ...1 year history each column represents 15 days column is written on 1st and 15th of a month...

Страница 4: ...cating that the display unit doesn t receive data from the sensor sensor is off or out of range SETTING MINIMAL AND MAXIMAL LEVELS To ensure proper measurement please set minimal and maximal level val...

Страница 5: ...ion will not trigger light or sound alarm Figure 8 Pump out relay mode Relay output can be inverted by selecting N C Normally Closed relay Type Relay modes HI and LO support Alarm option if this param...

Страница 6: ...ssing It is recommended to preform monthly backup of data to personal computer or any other memory storage device When using a new SD card it is recommended to format it in FAT32 and preform a test wr...

Страница 7: ...Reattach the front panel of the display unit and tighten four plastic screws do not use excessive force to tighten plastic screws...

Страница 8: ...screen Settings General Default Range Description Reset history No No Yes Reset history charts of the device Language English English Slovene Language of device interface Time and date Time 12 00 Time...

Страница 9: ...on audio visual alarm when relay is ON Off This relay is not connected to audio visual alarm Back Return to main settings menu Settings WiFi Default Range Description Scan for WiFi Scans for available...

Страница 10: ...range to AP No internet AP does not have connection to world wide web internet Check if device has sensor connected and is receiving data Interrupting and weak sensor signal check for obstructions be...

Страница 11: ...d insertion or settings change File types csv comma separated values Real time clock battery preinstalled 1 x 3 V CR2032 Lithium Models LW410 D receiver level display LW410XW D receiver level display...