Limited Warranty 

Navien, Inc. warrants the PeakFlow A Scale Prevention System as follows:
•  Navien warrants that the system is free of defects in material and workmanship for one year from the date of installation if 

the System is correctly installed according to the manual. 

Conditions

1.  The PeakFlow A Scale Prevention System works only when the incoming water complies with EPA regulations. Grease, 

copper, phosphate, silica, chlorine, and copper levels of the incoming water should meet the EPA drinking water 
standard.

2.  The concentration of chlorine of incoming water should not exceed 2.0 ppm. If water supply exceeds 2.0 ppm of 

chlorine, a pretreatment system must be used to reduce chlorine levels under 2.0 ppm.

3.  Abuse of the product, improper installation, or damage caused by the installer or user’s mistake shall void this warranty.
4.  The equipment must comply with local piping regulations and be installed and operated in a water supply system that 

complies with EPA drinking water standards.

5.  The equipment is restricted to use at the water pressure and temperature that does not exceed the specifications 

suggested by Navien, Inc.

6.  Information including the model number, serial number, and installation date must be provided for all claims related to the 

device warranty.

7.  Either Navien, Inc. or an authorized Navien representation shall inspect any allegedly defective parts. Navien, Inc. shall 

adjust the coverage.

8.  Navien, Inc. reserves the right to change or replace parts or equipment with materials of the same quality or value.

Содержание PeakFlow A

Страница 1: ...Flow Rate Up to 6 gpm 15 lpm Inlet Outlet Connections 1 FNPT Capacity Media cartridge does not have a grain removal capacity However other contaminants present in the water will gradually degrade the...

Страница 2: ...ll be damaged by high temperatures Be careful not to expose the system to freezing temperatures When the temperature drops below 40 F shut off the water supply to the housing and drain the housing Avo...

Страница 3: ...to the housing apply about 2 3 Teflon tape wraps to the threaded connections NOTE Do NOT use liquid pipe compounds to connect fittings Do not overtighten the housing entry and exit fitting connection...

Страница 4: ...be changed 36 months after installation and at least 36 months after the last filter change The frequency of cartridge replacement will depend on volume of system usage Media Replacement Procedure 1 T...

Страница 5: ...in the tank Remove the adapter from the mineral tank Temporary plug the open end of the rise The rise distributor remain inside the tank seated in the depression at the bottom Fill the gravel support...

Страница 6: ...s 2 0 ppm of chlorine a pretreatment system must be used to reduce chlorine levels under 2 0 ppm 3 Abuse of the product improper installation or damage caused by the installer or user s mistake shall...

Страница 7: ...K CORRECTLY OTHER COSTS RESULTING FROM LABOR CHARGES DELAYS VANDALISM NEGLIGENCE FOULING CAUSED BY FOREIGN MATERIAL DAMAGE FROM ADVERSE WATER CONDITIONS CHEMICALS OR ANY OTHER CIRCUMSTANCES OVER WHICH...

Отзывы: