LAKOS ILB/ILS Separators 

Installation Guide

Installation Instructions

LAKOS ILB/ILS Separators are shipped 

in heavy-duty cartons with plastic caps 

over the inlet and outlet to protect their 

male pipe threads. 

Prior to installation, the inlet, outlet 

and purge opening of each unit should 

be inspected for the presence of any 

foreign objects which may have entered 

the unit during shipping or storage.

Optional: Flush unit before operation.

Install piping to inlet and outlet.

For effective solids removal, LAKOS 

Separators must be operated within 

the recommended flow range for each 

model. Pipe size is not a factor in model

selection. Minimum inlet pressure 

should be at least 15 psi (1.0 bar) or 

LAKOS ILB/ILS Separators must be 

purged regularly to remove the separat-

ed solids from the temporary collection 

chamber. 

All purge hardware should be installed 

prior to any elbow or turns in the purge 

piping.

Avoid “uphill” purging, which can clog 

purge piping and hinder effective solids 

evacuation. 

For best results, purging is 

recommended while the LAKOS 

Separator is in operation, utilizing 

system pressure to enhance solids 

evacuation.

LAKOS offers a durable, reliable 

automatic purging system to eliminate 

routine maintenance. Frequency of 

purging and duration of purging are 

both programmable to accommodate 

the specific needs of virtually any 

application. 

Be sure to include an isolation valve 

prior to the automatic valve (available 

from LAKOS at an additional cost) to 

facilitate servicing of the automatic 

valve without system shut down.

equal to the pressure loss anticipated 

through the separator plus the system’s 

downstream pressure requirement.

LAKOS ILB/ILS Separators should be 

installed in the near upright vertical 

position on the discharge side of the 

pumping system. (Refer to factory 

for suction side installation.) Suitable 

means for supporting the separator’s 

weight independently from the inlet/

outlet piping is necessary. A LAKOS 

Mounting Kit is recommended (

See LS-

569 Mounting Bracket Kits

), but may be 

substituted with similar hardware, such 

as U-bolts fastened snuggly around the 

separator’s inner barrel.

If subject to idle periods, LAKOS ILB/

ILS Separators installed in sub-freezing 

locations must be drained of liquid or 

protected from freezing to avoid damage 

from ice expansion. NOTE: All

LAKOS automatic purging hardware 

provide a manual override to allow for easy 

draining via the purge opening.

Appropriate pressure gauges or differential 

pressure gauges are recommended to 

be connected at both inlet and outlet to 

monitor pressure loss and proper system 

flow. If the separator is operated at open 

discharge, a valve is recommended at 

the outlet, set to create a minimum back 

pressure of 5 psi (0.3 bar).

ILB/ILS

Maintenance/Purging