NHB Service Manual 35
Version 1.0
9. Entering <Error History mode> is available via
<Normal Operating mode>.
Item
Description
Display
1.
Normal
status
Normal
Operating
mode with
power On
When the current supply water
temperature is 120°F and the water
pressure is 12.3psi, the image
below repeats at 5 second intervals
(Fahrenheit specification)
Flashing
5 sec
psi
When the supply water
temperature is 60.0°C and its
water pressure is 12.3psi, the
image below repeats at 5 seconds
intervals. (Celsius specification)
Flashing
5 sec
psi
Item
Description
Display
2. Level1
Error
occurs
Level 1 Error
occurrence
status
When the current supply water
temperature is 120°F and its
water pressure is 12.3psi, the
image below repeats at 5 seconds
intervals. (Celsius specification)
Error icon flashes at 1 second
intervals.
5 sec flashing
psi
3. Level1
Error
displays
When a level
1 error occurs
When the current error is Level 1,
the 218 (error code will display for
5 seconds), Error icon flashes at 1
second intervals.
1 sec flashing after display of 5sec