100 Replacement of Parts
6.2.11 Water Pressure Sensor
1. Turn off the gas supply to the unit.
2. Turn off the 230V power supply to the unit.
3. Turn off the water supply to the unit. Drain all water from
the appliance.
4. Detach the wire connector the connects the water pressure
sensor.
Figure 21
5. Remove the clip on the WPS valve.
Figure 22
6. Replace with new water pressure sensor.
7. Connect the water pressure senor wire housing.
Note
Always use proper O-rings at the water pressure
valve connection to ensure tight seals.
6.2.10 3-way Valve
1. Turn off the gas supply to the unit.
2. Turn off the 230V power supply to the unit.
3. Turn off the water supply to the unit. Drain all water from
the appliance.
4. Detach the wire connector that connects the 3-way valve.
5. Remove the clip on the back of the 3-way valve.
Figure 19
6. Replace it with the new 3-way valve.
7. Connect the 3-way valve wire housing.
8. Turn on water supply, power supply, and gas supply to the
unit.
Содержание NCB500-2S/37K
Страница 3: ......
Страница 4: ...Revisions 3 Version Description of changes Date 1 00 First issue September 7 2022 Revisions...
Страница 115: ...Memo...
Страница 116: ...Memo...
Страница 117: ...Memo...
Страница 118: ...Memo...