8.4.2 Connecting the Cylinder Stat
The boiler is designed to be connected to a Cylinder Stat. The
thermostat cables are to be connected to the terminals 3 and 4
of the terminal block 1.
1
2
3
4
5
6
Detail View
8.4.3 Connecting the Outdoor Temperature
Sensor
The boiler is designed to be able to function with an outdoor
temperature sensor. The sensor cables are to be connected to
the terminals 5 and 6 of the terminal block 1.
1
2
3
4
5
6
Detail View
8.4.4 OpenTherm® Protocol
OpenTherm® is an industry standard modulating control
available from several control manufacturers and the NCB
LHWE boiler has an OpenTherm® interface. This enables
our modulating range of OpenTherm® room controls to be
NCB LHWE
OpenTherm® Protocol
Room Controller
1
2
3
4
5
6
8.5 Terminal block 2 Connection
The terminal block 2 is located below the front panel. External
devices powered by 230 VAC, such as a room stat and 3 port
diverter valve or 3-way valve, may be connected to the terminals
1-8, and the terminals 9 and 10 provide a low-voltage connection
for a cylinder temperature sensor. Refer to the following illustration
for details of the terminal block 2.
230 VAC
Room Stat
230 VAC
Output
3 port diverter valve
or 3-way valve
Cylinder Temp.
Sensor
L
Call
L
E
N
COM
(N)
DHW
(L)
CH
(L)
1
2
4
5
6
3
7
8
9
10
230 V live connections
Low-voltage
connections
CAUTION
230 VAC live voltage runs at terminals 1-8. Before
connecting devices to the terminal, ensure that the rated
Terminals 9 and 10 provide a low-voltage connection for
a cylinder temperature sensor.
38 Connecting Electrical Supplies