Model
Gas type
G20
G31
[20 mbar]
[37 mbar]
w
o
lf
s
a
G
w
o
lf
s
a
G
n
o
it
p
m
u
s
n
o
C
t
u
p
t
u
O
Load
Kcal/h
kW
kW
m
3
/h
m
3
/h
NCB-20LHWE
Max.
16,770
19.5
20.0
2.142
0.804
Min.
3,354
3.9
4.2
0.450
0.169
NCB-23LHWE
Max.
20,124
23.4
24.0
2.570
0.964
Min.
3,354
3.9
4.2
0.450
0.169
NCB-28LHWE
Max.
24,317
28.3
29.0
3.106
1.165
Min.
4,214
4.9
5.1
0.546
0.205
NCB-33LHWE
Max.
28,509
33.2
34.0
3.641
1.366
Min.
3,268
3.8
4.0
0.428
0.161
c. Fully open several hot water fixtures and set the boiler
to operate at 1-stage MIN mode.
Note
For operation mode selection, refer to “11.4
Setting the Operation Mode” on page 47.
Measure the CO
2
value at low fire.
If the CO
2
value is not within 0.5% of the value listed in
Table 2, the gas valve set screw will need to be adjusted.
If adjustment is necessary, locate the set screw as shown
in Figure 8. Using a
5
/
32
in or 4 mm Allen wrench, turn
the set screw no more than
1
/
4
turn clockwise to raise or
counterclockwise to lower the CO
2
value.
Figure 8. Set Screw Location
Note
The set screw is located behind the screw-on
cover. This must be removed first.
d. Fully open several hot water fixtures and set the boiler to
operate at C.MAX (20/23/28LHWE) or C.MAX2(33LHWE)
mode (refer to “11.4 Setting the Operation Mode” on
page 47). Measure the CO
2
value at high fire.
If the CO
2
values do not match Table 2 at high fire,
do not adjust the gas valve. Check for the proper Gas
Orifice.
DANGER
Improper gas valve settings can cause severe personal injury
or substantial property damage.
66 Appendices