CLEAN THE HYDRO-FILTER II: (If so equipped)
When used with the MX3-500HE, build-up of debris in the filter screen of the optional Hydro-Filter II will
reduce the vacuum air flow and may cause a significant decrease in water recovery. A torn filter screen will
allow debris past the filter and into the recovery tank. This debris can clog the Waste Pump and the Vacuum
Shutoff Assembly.
The Hydro-Filter II must be examined and cleaned regularly to keep the MX3-
500HE functioning properly:
•
Grasp and turn the lid counterclockwise to open the Hydro-Filter II lid.
•
Remove the filter screen. Examine the screen and clean or replace as needed.
•
Rinse the body of the Hydro-Filter II with clean water.
•
Examine the o-ring lid seal and replace as needed.
•
Re-install the new or cleaned screen.
•
Screw the lid back onto the body and turn clockwise to tighten.
RINSE OUT RECOVERY TANK:
Build-up of fine silt, sand and other debris in the recovery tank can damage the Drain Valve (and Waste
Pump if so equipped). Hair and fibers in the recovery tank can clog the vacuum filter (and Pump-out filter if
so equipped).Clean out the tank on a regular basis to extend the life of these components and to keep the
tank and machine smelling better.
•
Remove the recovery tank lid and open the drain valve.
•
Place a bucket under the drain valve.
•
Use a hose to rinse the dirt and debris out of the recovery tank.
•
Close the drain valve and spray the tank with a deodorizer or disinfectant.
•
Proceed to Waste Pump Cleaning and replace the recovery tank lid.
•
Dispose of the dirty water and debris.
Содержание HYDRO-FORCE MX3-500HE
Страница 1: ...1 LMANN18 REVISED 02 16 2018 MX3 500HE Nautilus Operating Manual...
Страница 36: ...36 Parts Replacementpartsavailableforrepairof yourMX3 500HE Section 3 KIT A PT054 KIT B PT055 KIT C PT056...
Страница 39: ...39 OPTIONAL AUTO FILL FLOAT VALVE ASSEMBLY NM5740...
Страница 40: ...40 Optional Pump Out Pump AP37F PARTS ASSEMBLY...
Страница 41: ...41 2 4 4 6 7 10 11 3 8 9 3 5 1 8 9 8 9 2 39 12 8 9...
Страница 44: ...44 44 37 46 46 47 47 48 50 9 50 9 52 51 53 TOP VIEW OF BASE 3 58 59 52 114 55 56 55 56 32 39 43 3 58 59 115 117...
Страница 45: ...45 48 49 49 47 47 47A 47A 47 47A 51 51 37 9 54 64 9 54 64 9 54 64 52 VACUUM MOUNTS CONNECTIONS 47 47A...
Страница 48: ...48 2 39 1 72 73 73 67 9 30 31 82 83 2 83 82 84 INSIDE SOLUTION TANK BOTTOM VIEW SOLUTION TANK...
Страница 50: ...50 96 91 97 9 88 111 94 105 93 OPTIONAL PUMP OUT CONNECTIONS 99 95 118...
Страница 51: ...51 FLOW 81 92 91 99 96 9 97 105 13 14A 14 95 OPTIONAL PUMP OUT PARTS 1 39 97 9 118...
Страница 52: ...52 HEATER PARTS 42 42A 98 114 110 71 113 114...