13
3. Priming the High-Pressure Pump:
Once water is in the solution tank, the high pressure pump must be primed:
•
There is a priming hose included with the machine. Connect the priming hose to the solution outlet –
female quick connect on the front of the machine.
•
Turn on both vacuums and the solution pump. Insert the end of the priming hose into the vacuum
inlet port on the front of the machine and cup your hand around the hose to block off the vacuum
inlet with your hand. The vacuum will pull solution through the pump and priming hose into the
vacuum tank.
•
Turn off the pump and then the vacuums. Disconnect the priming hose. You can now continue your
set-up. As long as there is solution in the tank, the pump should remain primed.
If the pump still does not prime, or if flow is low or unsteady, check the hose from the solution tank to the
pump (as well as the filter) for clogging, kinks, or restrictions. Clean or replace hose and/or filter and repeat
the priming procedure.
If you are having trouble with the pump, refer to the trouble shooting guide or contact your distributor for
advice or assistance.
4. Connection of Solution Hose:
Connect the high pressure solution hose to the solution outlet (female quick connect on the front of the
machine). Connect the other end of the hose to the male quick connect on the cleaning tool. When you are
ready to start cleaning, turn the solution pump switch to the ON position. The pressure is preset, there is no
pressure adjustment to be made.
Connect the male end of the HP Solution Hose
Assembly to the female solution outlet fitting on
the machine. Connect the female end to the
cleaning tool.
HP Solution Hose Assembly – AH79D
1/4” id X 25’ with M-F Quick Connects
PUMP PRIMING HOSE
NM5080
Содержание HYDRO-FORCE MX3-500HE
Страница 1: ...1 LMANN18 REVISED 02 16 2018 MX3 500HE Nautilus Operating Manual...
Страница 36: ...36 Parts Replacementpartsavailableforrepairof yourMX3 500HE Section 3 KIT A PT054 KIT B PT055 KIT C PT056...
Страница 39: ...39 OPTIONAL AUTO FILL FLOAT VALVE ASSEMBLY NM5740...
Страница 40: ...40 Optional Pump Out Pump AP37F PARTS ASSEMBLY...
Страница 41: ...41 2 4 4 6 7 10 11 3 8 9 3 5 1 8 9 8 9 2 39 12 8 9...
Страница 44: ...44 44 37 46 46 47 47 48 50 9 50 9 52 51 53 TOP VIEW OF BASE 3 58 59 52 114 55 56 55 56 32 39 43 3 58 59 115 117...
Страница 45: ...45 48 49 49 47 47 47A 47A 47 47A 51 51 37 9 54 64 9 54 64 9 54 64 52 VACUUM MOUNTS CONNECTIONS 47 47A...
Страница 48: ...48 2 39 1 72 73 73 67 9 30 31 82 83 2 83 82 84 INSIDE SOLUTION TANK BOTTOM VIEW SOLUTION TANK...
Страница 50: ...50 96 91 97 9 88 111 94 105 93 OPTIONAL PUMP OUT CONNECTIONS 99 95 118...
Страница 51: ...51 FLOW 81 92 91 99 96 9 97 105 13 14A 14 95 OPTIONAL PUMP OUT PARTS 1 39 97 9 118...
Страница 52: ...52 HEATER PARTS 42 42A 98 114 110 71 113 114...