49
Condition/Problem
Things to Check
Solution
No display/partial display/
unit will not turn on
Check electrical (wall)
outlet
Make sure unit is plugged into a functioning wall outlet.
Check connection at front
of unit
Connection should be secure and undamaged. Replace
adapter or connection at unit if either are damaged.
Check Power Switch
Turn on the power with the Power Switch.
Check data cable integrity All wires in cable should be intact. If any are visibly crimped or
cut, replace cable.
Check data cable
connections/orientation
Be sure cable is connected securely and oriented properly.
Small latch on connector should line up and snap into place.
Check console display for
damage
Check for visual sign that console display is cracked or other-
wise damaged. Replace Console if damaged.
Console Display
,I&RQVROHRQO\KDVSDUWLDOGLVSOD\DQGDOOFRQQHFWLRQVDUH¿QH
replace the Console.
If the above steps do not resolve the problem, contact Cus-
tomer Service (if inside US/Canada) or your local distributor (if
outside US/Canada).
Unit operates but Contact
HR not displayed
HR cable connection at
Console
Be sure cable is connected securely to Console.
+5FDEOHER[FRQQHFWLRQ
Be sure cables from handlebars and cable to Console are
secure and undamaged.
Sensor grip
Be sure hands are centered on HR sensors. Hands must be
kept still with relatively equal pressure applied to each side.
Dry or calloused hands
6HQVRUVPD\KDYHGLႈFXOW\ZLWKGULHGRXWRUFDOORXVHGKDQGV
A conductive electrode cream (heart rate cream) can help
make better conduct. These are available on the web or at
PHGLFDORUVRPHODUJHU¿WQHVVVWRUHV
Static Handlebar
If tests reveal no other issues, Static Handlebar should be
replaced.
Unit operates but
Telemetric HR not
displayed
Chest Strap (optional)
Strap should be “POLAR
®
” compatible and uncoded. Make
sure strap is directly against skin and contact area is wet.
Chest Strap Batteries
If strap has replaceable batteries, install new batteries.
&KHFN8VHU3UR¿OH
6HOHFWWKH(GLW8VHU3UR¿OHRSWLRQIRUWKH8VHU3UR¿OH*RWR
the WIRELESS HR setting and make sure that the current
value is set to ON.
Interference
Try moving unit away from sources of interference (TV, Micro-
wave, etc).
Replace Chest Strap
If interference is eliminated and HR does not function, replace
strap.
Replace Console
If HR still does not function, replace Console.
Unit operates but
Telemetric HR displayed
incorrectly
Interference
Make sure that the HR receiver is not blocked by a personal
electronic device in the left side of the media tray.
TROUBLESHOOTING
Содержание E618
Страница 1: ...ASSEMBLY MANUAL OWNER S MANUAL E618 E628 ...
Страница 13: ...13 4 Attach Legs to Frame Assembly F X2 22 13 A C G X2 6mm ...
Страница 21: ...21 14 Attach Front Handlebar Shrouds and Install Screws NOTICE Do not crimp cables J 2X J 2X ...
Страница 53: ...53 ...
Страница 54: ...54 ...
Страница 56: ... Nautilus RZÀH Schwinn EN ...