![Nautilus Hyosung MX5300CE Скачать руководство пользователя страница 72](http://html1.mh-extra.com/html/nautilus-hyosung/mx5300ce/mx5300ce_service-manual_3515387072.webp)
Chapter5. Power Supply Service Manual
5-4
©
Nautilus Hyosung, Inc.
All Rights Reserved.
Specifications
Environment Condition
▶
Environment Condition
Condition Operating Storage
Condition
Operating
Movement
Temperature
-5 ~ 55
℃
[23 ~ 131
℉
]
-20 ~ 75
℃
[-4 ~ 167
℉
]
Vibration 0.5G 2.0G
Humidity
20 ~ 90
℅
20 ~ 90
℅
Impact
5.0G
10.0G
M.T.B.F 30,000Hrs
Mechanical Specification
▶
Mechanical Specification
Dimension (Main)
240(L) x 95(W) x 70(H)
Case Color
-
Case Material
EGI 1.0t
Case Drawing No.
-
Weight
About 0.8Kg
Model Label
UL94-V2
Withstanding Voltage & Insulation Resistance
▶
Withstanding Voltage & Insulation Resistance
Division
Test Point
Test Input Voltage
Test Condition
Withstanding
Voltage
PRI – SEC
AC 3000 V
During the Test: 1 min
Cutoff Current: 10mA
PRI - F.G
AC 1800 V
Insulation
Resistance
PRI – SEC
DC 500 Vdc
During the Test: 1 min
Insulation Resistance:
≥
10Mohm
PRI - F.G
DC 500 Vdc
Safety: UL60950/IEC60950
Содержание MX5300CE
Страница 1: ...Service Manual MX5300CE System V01 00 03 2013 05 30 Nautilus Hyosung Inc All Rights Reserved...
Страница 59: ...Chapter4 Control Electronics Service Manual 4 8 Nautilus Hyosung Inc All Rights Reserved...
Страница 84: ...Chapter6 Safe Unit Service Manual 6 6 Nautilus Hyosung Inc All Rights Reserved Changing Batteries...
Страница 85: ...Service Manual Chapter6 Safe Unit Nautilus Hyosung Inc All Rights Reserved 6 7 Changing Batteries Option...