![Nautilus Hyosung MX5300CE Скачать руководство пользователя страница 33](http://html1.mh-extra.com/html/nautilus-hyosung/mx5300ce/mx5300ce_service-manual_3515387033.webp)
Chapter3. User Handling Unit Service Manual
3-12
© 2012
Nautilus Hyosung, Inc.
All Rights Reserved.
LED Operation Check
▶
There are 3 LEDs at the back of the EPP. With the status of these 3 LEDs, the EPP
operation condition can be easily checked.
NO
LED
DESCRIPTION
REMARK
1
LED1 (Power LED)
Whether the power supply is in “normal”
status
(If it is normal, red light will be turned on LED)
2
LED2 (Status LED)
Whether the EPP is in “normal” operation
(If it is normal, LED will blink)
3
LED5 (NV-RAM LED)
Whether the NV-RAM is properly cleared
(If it is normal, red light will turned on LED)
Troubleshooting
▶
Troubleshooting
1. Since the problem in this unit involves a security issue, you should replace the entire
unit when encountering a problem.
2. If a problem is confirmed, turn off the power, remove the power cable and bracket,
and then replace the unit with a new one. For the assembly of the unit, follow the
reverse order.
3. If LED1 is off, check the cable connection to see if the power supply is okay.
4. If LED1 is on and LED2 is off, it means EPP is in abnormal operation. Therefore,
replace the EPP.
Содержание MX5300CE
Страница 1: ...Service Manual MX5300CE System V01 00 03 2013 05 30 Nautilus Hyosung Inc All Rights Reserved...
Страница 59: ...Chapter4 Control Electronics Service Manual 4 8 Nautilus Hyosung Inc All Rights Reserved...
Страница 84: ...Chapter6 Safe Unit Service Manual 6 6 Nautilus Hyosung Inc All Rights Reserved Changing Batteries...
Страница 85: ...Service Manual Chapter6 Safe Unit Nautilus Hyosung Inc All Rights Reserved 6 7 Changing Batteries Option...