MoniMax 5100T 7. Appendix
7-
34
Error Code
Cause
Handling
DA01600
Withdrawal limit already reached
1. Check the limit amount of withdrawal.
2. Check the total paid money from ATM.
DA01700 Invalid
Amount
Check the input amount during transaction.
DA01800 External
decline
Inquire your service provider.
DA01900 System
error
Inquire your service provider.
DA02200
Message edit error
Inquire your service provider.
DA02300 Transaction
not
supported
Inquire your service provider.
DA11100 Reversal
Declined
Inquire your service provider.
DA01100 UNAUTHORIZED
TRANSACTION
Inquire your service provider.
DA01200
EXPIRED CARD (RBSLynk) or INVALID
SELECTED
TRANSACTION (STANDARD1/2) or
Amount too large (STANDARD3)
- EXPIRED CARD
Check the valid date of card.
- INVALID SELECTED TRANSACTION
Check the selected transaction
- AMOUNT TOO LARGE
Check the input amount during the transaction.
DA01300
INVALID (RBSLynk) or INVALID
AMOUNT (STANDARD1/2) or
ACCOUNT CLOSED (STANDARD3)
- INVALID
1. Reenter the password correctly.
2. If the same problem occurs, inject
master key again by diagnostics or
inquire your service provider.
- INVALID AMOUNT
Check the input amount during
transaction.
- ACCOUNT CLOSED
Check the account from bank.
DA01400
PIN ERROR (RBSLynk) or INVALID
CARD (COMMON)
- PIN ERROR
1. Reenter the password correctly.
2. If the same problem occurs, inject master key
again by diagnostics or inquire your service
provider.
- INVALID CARD
Check the card whether usage or not.
DA01500
BANK or NETWORK UNAVAILABLE
Inquire your service provider.
DA02000
SURCHARGE DISPLAY FAULT
Inquire your service provider.
DA02100
UNAUTHORIZED USE (STANDARD1/2)
or Routing lookup problem
(STANDARD3)
Inquire your service provider.
Содержание MoniMax 5100T
Страница 7: ...MoniMax 5100T 1 Introduction 1 1 Chapter 1 Introduction...
Страница 12: ...MoniMax 5100T 2 Precautions for Safety 1 2 Chapter 2 Precautions for Safety...
Страница 16: ...MoniMax 5100T 3 Hardware Specifications 3 1 Chapter 3 Hardware Specifications...
Страница 18: ...MoniMax 5100T 3 Hardware Specifications 3 3 2 Non Adjustor Type Fig 3 1 b Dimensions for Non Adjustor Type...
Страница 30: ...MoniMax 5100T 4 Operating Instructions 4 1 Chapter 4 Operating Instructions...
Страница 41: ...MoniMax 5100T 4 Operating Instructions 4 12...
Страница 43: ...MoniMax 5100T 5 Operator Function 5 1 Chapter 5 Operator Function...
Страница 89: ...MoniMax 5100T 6 Operator Function 6 1 Chapter 6 Operator Function with NDC...
Страница 108: ...MoniMax 5100T 6 Operator Function 6 20 Second screen shows the network setting information for the ATM and the host...
Страница 135: ...MoniMax 5100T 6 Operator Function 6 47 A 3 Operator mode A 3 1 REPLENISH...
Страница 143: ...MoniMax 5100T 6 Operator Function 6 55 a Enter the start date for the period b Enter the end date for the period...
Страница 148: ...MoniMax 5100T 6 Operator Function 6 60 A 4 TECHNICIAN MODE A 4 1 DIAGNOSTIC To execute the VDM...
Страница 149: ...MoniMax 5100T Option A DIAGNOSTICS A 1 Option A DIAGNOSTICS...
Страница 167: ...MoniMax 5100T Option B KEY MANAGEMENT B 1 Option B KEY MANAGEMENT...
Страница 180: ...MoniMax 5100T Option C Operator Function of H SPL C 1 Option C Operator Function of H SPL...
Страница 200: ...MoniMax 5100T Option D Operator Function of T SPL D 1 Option D Operator Function of T SPL...
Страница 217: ...MoniMax 5100T 7 Appendix 7 1 Chapter 7 Appendix...
Страница 224: ...MoniMax 5100T 7 Appendix 7 8 z Bill with folded lines 9 Case 1 9 Case 2 9 Case 3 Bill distortion should not exceed 10 mm...
Страница 272: ...MoniMax 5100T 7 Appendix 7 56 Fig 7 7 Making a surface level of ATM...
Страница 277: ...MoniMax 5100T 7 Appendix 7 61...