background image

BATHROOM FAN – THEIA 70 CFM WITH 1 LIGHT

3

Dimensions

Dimensions requirements

CEILING OPENING ( L )

CEILING OPENING ( W )

CEILING OPENING ( H )

8 in

8 in

7 in

Specifications

MODEL

NO.

AIR

DIRECTION

V

HZ

DUCT

DIAMETER

NOISE

(SONE)

POWER

CONSUMPTION

SPEED

(RPM)

WEIGHT

THEIA 70 L

70 CFM

120

60

4” (10 cm)

3

48 W

1500

4.5 lbs  (2.04 kg)

• For an average ductwork which is 10’ to 15’ (3 m to 4,6 m) long, 4” (10 cm) in diameter with the assumption of a 8’ (2.4 m) high ceiling.
• Incandescent or compact fluorescent light bulbs: 1 x 13 W  with GU24 socket connectors.
• 70 CFM = 70 square feet.
• If the area is larger, you may use a fan providing a greater CFM.

Limited warranty

LIGHTBULB ONLY LIMITED WARRANTY: 

The 13 W, GU24 base lightbulb included in the THEIA 70 L bathfan box is guarantied one (1) year based on normal household usage. If this bulb does not last 

for the time period guaranteed (based on 3 hours average usage per day / 7 days per week) return bulb, proof of purchase, register receipt and your name and 

address to NAUTIKA and we will replace the bulb. This replacement is the sole remedy available, and LIABILITY FOR DIRECT, INCIDENTAL OR CONSEQUENTIAL 

DAMAGES IS HEREBY EXPRESSLY EXCLUDED.

WHAT THIS BATHFAN WARRANTY COVERS: 

This product is warranted against defects in workmanship and/or materials.

HOW LONG THIS BATHFAN WARRANTY LASTS: 

This warranty extends only to the original purchaser of the product and lasts for one (1) year from the date of original purchase or until the original purchaser of 

the product sells or transfers the product, whichever first occurs.

WHAT NAUTIKA WILL DO:

 

During the warranty period, Nautika will, at its sole option, repair or replace any part or parts that prove to be defective or replace the whole product with the 

same or comparable model.

WHAT THIS BATHFAN WARRANTY DOES NOT COVER:

  

This warranty does not apply if the product was damaged or failed because of accident, improper handling or operation, shipping damage, abuse, misuse, 

unauthorized repairs made or attempted. Nautika will pay return shipping charges to Nautika warehouse in warranty replacement cases.

Some states and provinces do not allow limitations on how long an implied warranty lasts, or the exclusion or limitation of incidental or consequential damages, 

so these exclusions or limitations may not apply to you. This warranty gives you specific legal rights. You may also have other rights which vary from state to state 

and province to province. Proof of purchase is required before a warranty claim will be accepted.

Содержание THEIA 70 CFM

Страница 1: ...with a built in thermal cut off for safety and to prolong the life of the motor PREPARATION Tools Required for Assembly not included Hammer Drill Bits Flathead Screwdriver Wire Nuts Nails Duct Tape Phillips Screwdriver Utility Knife Helpful Tools not included Electric Drill Wood Screws Carefully remove unit from carton Check area above installation location to be sure that wiring can run to the pl...

Страница 2: ...e local building code authorities 9 Do not use this fan with any solid state control device such as a remote control dimmer switch or certain timers Mechanical timers are not solid state devices 10 This ventilation fan is approved for use over a bathtub or shower when installed in a GFCI protected circuit Do not use fans over a bathtub or shower that are not approved for that application and marke...

Страница 3: ...Y EXCLUDED WHAT THIS BATHFAN WARRANTY COVERS This product is warranted against defects in workmanship and or materials HOW LONG THIS BATHFAN WARRANTY LASTS This warranty extends only to the original purchaser of the product and lasts for one 1 year from the date of original purchase or until the original purchaser of the product sells or transfers the product whichever first occurs WHAT NAUTIKA WI...

Страница 4: ...hang down from joist 3 4 in 2 Mounting fan body Use long wood screws BB to loosely attach both sides of main body to joist right side shown Ensure ventilation fan A is level and that proper clearance is given for finished ceiling board When main body A is level and in the intended location tighten screws BB on both right and left side of main body BB Long wood screw x 2 NOTE Important wire informa...

Страница 5: ...our ability to correctly install wiring 4 Connecting duct work Install a circular duct to outlet and secure it with duct tape or clamps Install duct work in a straight line with minimal bends Fan must be ventilated to the exterior 5 Attach the light box connector to the empty socket provided in the fan housing There is only one possible way to connect to the connector shapes 6 Installing the fan g...

Страница 6: ...ss to an exterior air outlet wall cap or roof jack Ensure you will not have to use sharp angles or very long duct Make sure the ductwork in the chosen place will not interfere with any other existing ductwork in the building Make sure there is no electrical wiring or pipes behind the chosen place After finding the optimal place proceed with the opening Ensure the support beams are strong enough to...

Страница 7: ... l assemblage non inclus marteau tournevis à tête plate capuchons de connexion clous ruban à conduits tournevis cruciforme et couteau à lame rétractable Outils utiles non inclus perceuse électrique et forets Retirez soigneusement l appareil de la boîte Inspectez l emplacement au dessus de l endroit où vous désirez installer l appareil pour vous assurer que le câblage peut se rendre à l endroit pré...

Страница 8: ...cal du bâtiment 9 N utilisez pas ce ventilateur avec un dispositif de réglage à semi conducteurs comme une télécommande un gradateur ou certains types de minuterie Les minuteries mécaniques ne sont pas des dispositifs de réglage à semi conducteurs 10 Ce ventilateur d aération est approuvé pour une utilisation au dessus d une baignoire ou d une douche s il est installé sur un circuit électrique pro...

Страница 9: ...INDIRECTE de NAUTIKA est expressément exclue QUE COUVRE CETTE GARANTIE DE VENTILATEUR Ce produit est garanti contre tout vice de fabrication ou de matière COMBIEN DE TEMPS CETTE GARANTIE DE VENTILATEUR DURE Cette garantie se rapporte seulement à l acheteur original du produit et dure pendant un 1 an de la date de l achat original ou jusqu à ce que l acheteur original du produit vend ou transfère l...

Страница 10: ...teur Utilisez des vis à bois longues BB pour attacher de manière lâche les deux côtés du corps principal du ventilateur aux solives côté droit illustré Vérifiez que le ventilateur d aération est de niveau et qu un espace suffisant a été réservé pour le panneau plafond fini Lorsque le corps principal A est de niveau et à l emplacement désiré serrez les vis BB sur les deux côtés droit et gauche du c...

Страница 11: ...a sortie et fixez le avec du ruban adhésif ou des colliers pour conduit Installez le conduit d aération selon une ligne droite avec le moins de coudes possibles Le ventilateur doit évacuer vers l extérieur 5 Attacher le connecteur du boîtier de lumière à la prise vide prévue à cet effet dans le boîtier du ventilateur Il n y a qu un seul sens possible pour la connection avec les formes du connecteu...

Страница 12: ... year warranty against any manufacturing defects as long as it is used according to its intended use Canac will exchange any product that would show any such manufacturing defects Made in China and packaged exclusively for Canac P O Box 400 L Ancienne Lorette Québec G2E 4W6 Illustration 1 Secure with duct tape Illustration 2 Wrong support Illustration 3 Rights support and angle VENTILATEUR DE SALL...

Отзывы: