VS300 Operations and Maintenance Manual
Operating the transmitter
Page 2-114
Issue 8.0 2016-03-01
Figure 2.95: System Settings - OS Recovery Screen
Use the up and down buttons to toggle between
Force OS Recovery
and
Cancel
. Press the accept
(checkmark) button to save the change. Select
Cancel
or press
X
to abort the recovery and return to
the previous menu.
Configuring Host Watchdog
From the front panel UI, you can enable or disable the host watchdog feature. This feature, when
enabled, monitors communication between the ARM processor and the DSP processor on the
exciter/control PWB. If communication is lost for more than 30 seconds, the transmitter will initiate
an alarm and reboot the host. To view the
Host Watchdog
screen, select
System Settings -> Host
Watchdog
from the
Main Menu
).
Figure 2.96: System Settings - Host Watchdog Screen
Use the up and down buttons to toggle between
OFF
and
ON
. Press the accept (checkmark) button to
save the change. Press cancel (
X
) to discard changes and return to the previous menu
Note:
Host watchdog configuration is only available using the front panel UI.
Содержание VS300
Страница 2: ......
Страница 4: ......
Страница 8: ...VS300 Operations and Maintenance Manual Page viii Issue 8 0 2016 03 01...
Страница 14: ...VS300 Operations and Maintenance Manual Description Page 1 6 Issue 8 0 2016 03 01...
Страница 16: ...VS300 Operations and Maintenance Manual Issue 8 0 2016 03 01 Page 1 8 Figure 1 2 Block Diagram VS300 Audio Path...
Страница 20: ...VS300 Operations and Maintenance Manual Operating the transmitter Page 2 4 Issue 8 0 2016 03 01...
Страница 228: ......