VS1 Troubleshooting Manual
Responding to alarms
Page 1-32
Issue 10.0 2018-10-29
Preparation for replacing a PWB or module
1. Disable the VS1’s RF output (RF off) and set its
AC POWER
switch to the off position.
Disconnect all cabling from the rear of the VS1, remove the VS1 from its host cabinet and
place the VS1 on a suitable work surface.
2. Based on the alarm that prompted troubleshooting, replace the appropriate PWB, module or
cooling fan (see the appropriate replacement procedure in
Table 1.5 on page 1-32
).
Table 1.5: Replacement Procedures
NOTE:
If a power amplifier (PA) failure occurs, you must replace the entire power
amplifier PWB, rather than an individual FET. A spare PA PWB (NAPA23/
03A) is provided in the transmitter station spares kit, if purchased. To order a
station spares kit contact Nautel. Failure to observe this recommendation may
void your equipment warranty or cause further failures.
Module
Replacement Procedure
PA PWB
See
page 1-33
Pre-amp/IPA PWB
See
page 1-36
Power Supply Module
See
page 1-39
+48 V Power Supply
See
page 1-40
Cooling Fan
See
page 1-41
Exciter/Control PWB
See
page 1-43
PS Distribution PWB
See
page 1-46
Combiner Interface PWB
See
page 1-47
Содержание VS1
Страница 1: ...VS1 Transmitter Troubleshooting Manual Document NHB VS1 TRB Issue 10 0 2018 10 29 Status Standard...
Страница 2: ......
Страница 4: ......
Страница 8: ...VS1 Troubleshooting Manual Page viii Issue 10 0 2018 10 29...
Страница 56: ...VS1 Troubleshooting Manual Responding to alarms Page 1 48 Issue 10 0 2018 10 29...
Страница 84: ...VS1 Troubleshooting Manual Wiring connector lists Page 4 6 Issue 10 0 2018 10 29...
Страница 102: ...Issue 10 0 2018 10 29 MD 7 Figure MD 7 NAPA23 03A PA PWB C16 R13 R12 C5 C8...
Страница 108: ......