VS1 Troubleshooting Manual
Responding to alarms
Issue 10.0 2018-10-29
Page 1-27
Power Supply
This summary alarm is triggered if any of the following power supply related
alarms occur:
Discharging PA Volts
PS A Over Temp
+1.8V Fail
PA Volts Fail
Residual PA Volts P3.3V Fail
PS A AC Fail
+1.2V Fail
+48V Fail
PS A Fail
+15V Fail
+5V Fail
PS A Missing
-15V Fail
Reduced Power
This summary alarm is triggered if any of the following reduced power related
alarms occur:
Cutback Active
High Temperature Latch
Fan 1 - 3 Fail
PA Over Temperature
Forward Power Limiting
PA Pwr Foldback
Forward Power Low
Reject Foldback
Forward Power Very Low
SWR Foldback
HD PA Fault Foldback
PA 1 - 4 Fail
Table 1.2: Troubleshooting Summary Alarms
Summary Alarm
Name
Description and Triggering Alarms
Содержание VS1