NX50 Operations and Maintenance Manual
Operating the transmitter
Page 2-98
Issue 3.3 2016-02-08
RF Monitor Level
The
RF Monitor Level
page allows you to set values for the
Gain at Full Power
(in dB) (see
) on the amplifier that drives the
RF Monitor
output. The RF monitor is factory set to
provide a level of 5 V rms into 50 ohm (27 dBm).
The
Current Gain
value is shown for reference. Increase the gain to increase the RF monitor output
level; decrease the gain to decrease the RF monitor output level. The transmitter will attempt to
maintain this level at all power set points (see
Figure 2.71: System Settings - RF Monitor Level
Procedure to set the RF monitor level:
1. Select the
RF Monitor Level
option from the left side of the
System Settings
page to
open a related window on the right side of the page.
2. Observe the
Current Gain
value and its corresponding RF monitor level (measured). Enter
the new
Gain at Full Power
value to increase or decrease the RF monitor level.
3. Press
Apply
. Verify the measured RF monitor level is as desired. Readjust as necessary.
Содержание NX50
Страница 2: ......
Страница 4: ......
Страница 8: ...NX50 Operations and Maintenance Manual Page viii Issue 3 3 2016 02 08...
Страница 17: ...NX50 Operations and Maintenance Manual Description Issue 3 3 2016 02 08 Page 1 9 Figure 1 4 Shutback Event...
Страница 19: ...NX50 Operations and Maintenance Manual Issue 3 3 2016 02 08 Page 1 11 NX Series Transmitter Block Diagram...
Страница 150: ...NX50 Operations and Maintenance Manual Operating the transmitter Page 2 132 Issue 3 3 2016 02 08...
Страница 156: ...NX50 Operations and Maintenance Manual Routine maintenance Page 3 6 Issue 3 3 2016 02 08...
Страница 162: ...NX50 Operations and Maintenance Manual Non standard maintenance Page 4 6 Issue 3 3 2016 02 08...
Страница 165: ......