NX5 PRE-INSTALLATION MANUAL
PLANNING CONTROL/MONITOR CONNECTIONS
VERSION 0.1 2015-08-01
PAGE 1.8.5
Option 2 - External Dc Supply
If you plan to use an external dc voltage (12 V to 18 V) as the source for the remote inputs, the type of
connections to the control/interface PWB (A4) are shown in
When the remote input is configured for ‘falling edge’ or ‘active low’ logic, dc voltage must be applied
between J6A-9/21 and the appropriate remote input (1 through 10). When the remote input is
configured for ‘rising edge’ or ‘active high’ logic, an open circuit (no dc voltage) must be applied to the
appropriate remote input (1 through 10).
Figure 1.8.2: External Dc Supply Selected (E1 jumper set to EXT)
The momentary switch should be located between the dc supply's negative output and the digital input.
1
2
3
S2120501 V1
J6A-9/21
EXT
E1
+15V
DC SUPPLY
REMOTE SELECTION CIRCUITRY
CONFIGURED FOR EXTERNAL
REMOTE INPUT (01 TO 10)
PWB
PWR SUPPLY
(+12V TO +18V)
CONTROL/
INTERFACE
EXTERNAL DC
NOTE
: The selected configuration is
detemined by a single jumper setting
(E1) on the control/interface PWB and
applies to all remote inputs (1 through
10). They cannot be configured sepa-
rately.
Содержание NX5 AM
Страница 2: ......
Страница 4: ......
Страница 8: ...NX5 PRE INSTALLATION MANUAL TABLE OF CONTENTS PAGE 1 VIII VERSION 0 1 2015 08 01 ...
Страница 10: ...NX5 PRE INSTALLATION MANUAL PAGE 1 X VERSION 0 1 2015 08 01 ...
Страница 22: ...NX5 PRE INSTALLATION MANUAL PAGE 1 XXII VERSION 0 1 2015 08 01 ...
Страница 75: ...NX5 PRE INSTALLATION MANUAL PLANNING CONTROL MONITOR CONNECTIONS PAGE 1 8 16 VERSION 0 1 2015 08 01 ...
Страница 79: ...NX5 PRE INSTALLATION MANUAL PARTS AND TOOLS PAGE 1 9 4 VERSION 0 1 2015 08 01 ...
Страница 85: ...NX5 PRE INSTALLATION MANUAL PRE INSTALLATION ASSISTANCE PAGE 1 10 6 VERSION 0 1 2015 08 01 ...
Страница 88: ......