NX25/NX15 Troubleshooting Manual
Responding to alarms
Issue 5.0 2016-05-06
Page 1-11
Controller: External PDM
Inhibit
This alarm occurs if the external PDM inhibit circuit, wired to the
control/interface PWB, is closed. When this alarm occurs, the
transmitter immediately inhibits the PDM and the transmitter's
output power drops to 0 W. The transmitter will automatically
recover when the condition is cleared. Ensure the transmitter is
set to RF Off and disconnect the PDM inhibit circuit from the
transmitter. Measure the impedance of the interlock circuit. If the
impedance measures short circuit (low impedance) the PDM
inhibit is closed, and it will be necessary to locate the external
device that is causing this condition. If the impedance does not
measure short circuit, verify the PDM inhibit circuitry has been
properly configured. If the PDM inhibit circuitry is properly
configured and the alarm persists, replace the control PWB (see
“Controller: External PDM Inhibit” on page 1-41
Controller: External
Reset
This alarm is only visible in the transmitter logs, and indicates the
controller was reset by triggering the controller's reset pin. If this
alarm continues to occur unexpectedly, replace the control/
interface PWB
“Control/interface PWB replacement” on
Controller: Fast SWR
Shutback
This alarm indicates the peak reflected power measured by the
directional coupler at the output of the transmitter has exceeded
the factory-set threshold. When this alarm occurs, the transmitter
immediately inhibits the PDM and RF drive
(see
of the Operations & Maintenance Manual). Once the
fault clears, the transmitter will automatically recover, either to the
power setpoint, or to a reduced power as determined by the
cutback routine
(see
of the Operations &
Maintenance Manual). If this alarm occurs in conjunction with the
Exciter's SWR Shutback alarm, it generally indicates a fault in the
transmitter's external RF output network (e.g., rigid-line, antenna,
etc.). If this alarm is occurring while the Exciter's SWR Shutback
alarm is not, verify the wiring between the directional coupler and
the control/interface PWB is not damaged. If not, verify the Fast
SWR Shutback threshold is set properly (contact Nautel to obtain
the correct setting for your transmitter). If this threshold is set
correctly and the alarm persists, replace the control/interface
PWB (see
“Control/interface PWB replacement” on page 1-60
).
Alarm (with Prefix)
Description and Troubleshooting Action
Содержание NX15
Страница 2: ......
Страница 4: ......
Страница 8: ...NX25 NX15 Troubleshooting Manual Page viii Issue 5 0 2016 05 06...
Страница 78: ...NX25 NX15 Troubleshooting Manual Responding to alarms Page 1 70 Issue 5 0 2016 05 06...
Страница 96: ...NX25 NX15 Troubleshooting Manual Detailed Circuit Descriptions Page 2 18 Issue 5 0 2016 05 06...
Страница 104: ...NX25 NX15 Troubleshooting Manual Parts Lists Page 3 8 Issue 5 0 2016 05 06...
Страница 216: ...NX25 NX15 Troubleshooting Manual Wiring connector lists Page 4 12 Issue 5 0 2016 05 06...
Страница 222: ...NX25 NX15 Troubleshooting Manual Reading Electrical Schematics Page 5 6 Issue 5 0 2016 05 06...
Страница 250: ...Issue 5 0 2016 05 06 MD 1 Figure MD 1 NX15 NX25 Transmitter Front View...
Страница 251: ...Issue 5 0 2016 05 06 MD 2 Figure MD 2 NX15 NX25 Transmitter Rear View...
Страница 254: ...Issue 5 0 2016 05 06 MD 5 Figure MD 5 NAE96C 01 Control Exciter Panel...
Страница 257: ...Issue 5 0 2016 05 06 MD 8 Figure MD 8 NAPI106 Remote Interface PWB...
Страница 261: ...Issue 5 0 2016 05 06 MD 12 Figure MD 12 NAPI98 RF Drive Distribution PWB...
Страница 263: ...Issue 5 0 2016 05 06 MD 14 Figure MD 14 NAX243A B Distribution Assembly...
Страница 265: ...Issue 5 0 2016 05 06 MD 16 Figure MD 16 NAPA34A Modulator Power Amplifier PWB Front View...
Страница 267: ...Issue 5 0 2016 05 06 MD 18 Figure MD 18 Fan Tray Assembly 207 8133...
Страница 268: ...Issue 5 0 2016 05 06 MD 19 Figure MD 19 Voltage Probe 207 6111...
Страница 269: ...Issue 5 0 2016 05 06 MD 20 Figure MD 20 Current Probe 207 6213 04...
Страница 270: ...Issue 5 0 2016 05 06 MD 21 Figure MD 21 NAFP106B 02 Directional Coupler A1 DETAIL...
Страница 273: ......