NX25/NX15 Troubleshooting Manual
Responding to alarms
Issue 5.0 2016-05-06
Page 1-7
Controller: Combiner
Interlock Open
This alarm will only occur if the transmitter is connected in a
combined system. The alarm indicates that the interlock signal
from the combiner is open. When this alarm occurs, the
transmitter immediately inhibits the PDM and the transmitter's
output power drops to 0 W. If this condition persists for more than
10 seconds, the transmitter will inhibit the RF power modules,
fans and B+ power supply. The transmitter will automatically
recover when the condition is cleared. Check the combiner for a
condition that may cause it to open the interlock to the transmitter.
If so, troubleshoot the cause of that condition. If not, inspect the
wiring between the combiner and the transmitter and verify there
is no damage. If the alarm persists, replace the control/interface
PWB
“Control/interface PWB replacement” on page 1-60
).
Controller: Controller
Reset
This alarm is only visible in the transmitter logs, and indicates the
controller was reset because its +5 V power supply voltage was
less than 1.4 V, which normally happens due to a loss of ac power.
If the controller is rebooting without losing ac power to the
transmitter, check for the presence of other alarms at the time of
the controller reset and follow the troubleshooting information for
those alarms. Otherwise, replace the control/interface PWB
(see
“Control/interface PWB replacement” on page 1-60
).
Alarm (with Prefix)
Description and Troubleshooting Action
Содержание NX15
Страница 2: ......
Страница 4: ......
Страница 8: ...NX25 NX15 Troubleshooting Manual Page viii Issue 5 0 2016 05 06...
Страница 78: ...NX25 NX15 Troubleshooting Manual Responding to alarms Page 1 70 Issue 5 0 2016 05 06...
Страница 96: ...NX25 NX15 Troubleshooting Manual Detailed Circuit Descriptions Page 2 18 Issue 5 0 2016 05 06...
Страница 104: ...NX25 NX15 Troubleshooting Manual Parts Lists Page 3 8 Issue 5 0 2016 05 06...
Страница 216: ...NX25 NX15 Troubleshooting Manual Wiring connector lists Page 4 12 Issue 5 0 2016 05 06...
Страница 222: ...NX25 NX15 Troubleshooting Manual Reading Electrical Schematics Page 5 6 Issue 5 0 2016 05 06...
Страница 250: ...Issue 5 0 2016 05 06 MD 1 Figure MD 1 NX15 NX25 Transmitter Front View...
Страница 251: ...Issue 5 0 2016 05 06 MD 2 Figure MD 2 NX15 NX25 Transmitter Rear View...
Страница 254: ...Issue 5 0 2016 05 06 MD 5 Figure MD 5 NAE96C 01 Control Exciter Panel...
Страница 257: ...Issue 5 0 2016 05 06 MD 8 Figure MD 8 NAPI106 Remote Interface PWB...
Страница 261: ...Issue 5 0 2016 05 06 MD 12 Figure MD 12 NAPI98 RF Drive Distribution PWB...
Страница 263: ...Issue 5 0 2016 05 06 MD 14 Figure MD 14 NAX243A B Distribution Assembly...
Страница 265: ...Issue 5 0 2016 05 06 MD 16 Figure MD 16 NAPA34A Modulator Power Amplifier PWB Front View...
Страница 267: ...Issue 5 0 2016 05 06 MD 18 Figure MD 18 Fan Tray Assembly 207 8133...
Страница 268: ...Issue 5 0 2016 05 06 MD 19 Figure MD 19 Voltage Probe 207 6111...
Страница 269: ...Issue 5 0 2016 05 06 MD 20 Figure MD 20 Current Probe 207 6213 04...
Страница 270: ...Issue 5 0 2016 05 06 MD 21 Figure MD 21 NAFP106B 02 Directional Coupler A1 DETAIL...
Страница 273: ......