Remove and retain six sets of mounting hardware from the remote interface PWB. Remove the
remote interface PWB from the transmitter.
6.
Locate or obtain a replacement remote interface PWB (Nautel Part # NAPI143/01).
7.
Set jumpers E1 and E2 on the new remote interface PWB to the same positions as the defective
PWB.
8.
As applicable, use an indelible marker to identify the LED and switch labels on the new remote
interface PWB to match the labels on the defective PWB.
9.
Install the new remote interface PWB using retained hardware.
10. Reconnect D-sub connectors W20P2 and W21P2, Cat5E connector W29P2 and all customer
interface wiring to the new remote interface PWB.
11. Return the transmitter to service.