background image

Note

If the HI-PRO 2 unit is connected to the PC via a USB hub, the hub must

be self-powered (have a separate power supply). This is to ensure that the USB
hub can deliver enough current for proper operation of the HI-PRO 2 unit.

3.3

Starting up HI-PRO 2

When the HI-PRO 2 Installation CD is installed, HI-PRO 2 powers on as soon as the
unit is connected to the PC and the PC is powered ON.

During power-up, the LEDs next to the connectors on the front panel will flash
once indicating that a brief self-test is in progress.

When the self-test is completed, only the power LED will light. If only the left LED
flashes, the self-test has failed and you should try powering on again. Should the
unit fail again, contact your local distributor.

The HI-PRO 2 connector LEDs will also light up when a hearing instrument is being
programmed, indicating which side is active.

The LED above the text ‘PC Com’ lights up to indicate communication with the PC.

Caution

Do not attempt to connect or disconnect a hearing instrument

while the connector LED is active! The LED indicates that the connector is act-
ive, and this might damage the hearing instrument.

Caution

Even though the hearing instrument connectors on the front of the

HI-PRO 2 are galvanically insulated from the PC and mains earth, it is still pos-
sible to release an electrostatic discharge (ESD) to a connected hearing instru-
ment, and through the HI-PRO 2 to earth. An electrostatic discharge can be
very uncomfortable for the client because it feels like a minor "electric shock",
and can even produce loud pulses of noise. Cases of electrical damage to hear-
ing instruments have been reported. It is recommended to install the unit in
an environment that minimizes the amount of static electricity. For example,
anti-static carpeting is recommended.

3.4

Disconnecting HI-PRO 2 from the PC

HI-PRO 2 automatically powers off together with the PC, but if you wish to power
off the HI-PRO without powering off the PC, you can disconnect the USB cable from

8

Otometrics - HI-PRO 2

Содержание otometrics HI-PRO 2

Страница 1: ...HI PRO 2 Installation Manual Doc No 7 50 0980 EN 03 Part No 7 50 09800 EN...

Страница 2: ...d Otometrics the Otometrics Icon AURICAL MADSEN Otoscan ICS and HORTMANN are registered trademarks of Natus Medical Denmark ApS in the U S A and or other countries Version release date 2019 02 05 2068...

Страница 3: ...ble of Contents 1 Introduction to HI PRO 2 4 2 When you receive HI PRO 2 5 3 Installation 6 4 Service and Maintenance 9 5 Technical Specifications 10 6 Safety 18 7 Manufacturer 20 Otometrics HI PRO 2...

Страница 4: ...les for connecting hearing instruments to HI PRO 2 are supplied by the hearing instrument manufacturer 1 1 Intended use HI PRO 2 is intended for audiologists hearing instrument dispensers and other he...

Страница 5: ...ient or risk of damage to data or the device Note Indicates that you should take special notice 2 When you receive HI PRO 2 2 1 Unpacking and inspection 1 Unpack your HI PRO carefully When you unpack...

Страница 6: ...ollow the guidelines below Store HI PRO 2 and accessories in the box provided to protect the equipment from damage Store HI PRO 2 as stated in Technical Specifications 3 Installation Site the HI PRO 2...

Страница 7: ...y double clicking the icon on the desktop double click on the CD drive icon then double click on the Setup application icon to start the installation Follow the instructions on the screen 3 2 Connecti...

Страница 8: ...icate communication with the PC Caution Do not attempt to connect or disconnect a hearing instrument while the connector LED is active The LED indicates that the connector is act ive and this might da...

Страница 9: ...o circumstances disassemble HI PRO 2 Contact your supplier Parts inside HI PRO 2 must only be checked or serviced by authorized personnel Warning Do not disassemble the HI PRO 2 as there is a risk of...

Страница 10: ...port is used for communication between a PC and the HI PRO 2 unit Communication USB 2 0 full Speed USB 1 1 compatible USB Connector Type Type B connector on the HI PRO 2 unit Power Supply The HI PRO...

Страница 11: ...hearing instrument must meet the following requirements No conductive parts may be accessible when the programming cable is con nected to HI PRO 2 unit The programming cable and the connector must pr...

Страница 12: ...t Size L x W x H 137 mm x 114 mm x 37 mm 5 39 inch x 4 49 inch x 1 46 inch Net weight 230g 0 43 lb 5 1 Accessories Item Part number 1072 HI PRO 2 Installation CD 8 49 91200 USB Cable 3 meters 8 71 791...

Страница 13: ...ower supply network that supplies buildings used for domestic pur poses Guidance and manufacturer sdeclaration electromagnetic immunity for all equipment and systems HI PRO 2 is intended for use in th...

Страница 14: ...GHz 10 V m 80 MHz to 2 7 GHz Proximity fieldsfrom RF wirelesscom munications IEC 61000 4 3 27 V m 386 MHz 28 v m 450 MHz 9 v m 710 MHz 745 MHz 780 MHz 28 v m 810 MHz 870 MHz 930 MHz 28 v m 1720 MHz 18...

Страница 15: ...lies buildings used for domestic pur poses Guidance and manufacturer sdeclaration electromagnetic immunity for all equipment and systems HI PRO 2 is intended for use in the electromagnetic environment...

Страница 16: ...HI PRO 2 including cables than the recommended separation distance cal culated from the equation applicable to the frequency of the transmitter Recommended separation distance d 1 2 d 1 2 for 80 MHzt...

Страница 17: ...e is observed additional measures might be necessary such as reorienting or relocating HI PRO 2 b Over the frequency range 150 kHz to 80 MHz field strengths should be less than 3 V m Recommended separ...

Страница 18: ...1 2005 AMD1 2012 and EN 60601 1 2006 A1 2013 Class II equipment Follow instructions for use Consult user manual for warnings and cautions Complies with Medical Devices Directive 93 42 EEC and RoHS Di...

Страница 19: ...s When connecting equipment to the USB connector the following must be considered Equipment must be certified to relevant EN IEC safety stand ards e g EN IEC 60950 Use of connected equipment in a pati...

Страница 20: ...f HI PRO 2 6 No parts may be eaten burnt or in any way used for purposes other than the fitting of hearing aids or similar devices 7 For safety reasons and due to effects on EMC accessories connected...

Страница 21: ...arried out by the equipment manufacturer or personnel authorized by the man ufacturer The electrical installation to which the equipment is connected complies with EN IEC requirements The equipment is...

Страница 22: ......

Отзывы: