Control Panel 

              

 

3.  INSTALLATION 

DANGER:

 All wiring should be done by a certified technician or electrician to ensure 

adherence to the applicable electrical safety wiring regulations and installation codes. 

Failure to follow these instructions can damage the unit and could also result in personal 

injury or loss of life.

 

CAUTION:

 

Before beginning unit installation, please consider the following:

 

  The unit should be used or stored in an indoor area away from direct sunlight, heat, moisture 

or conductive contaminants. 

  When placing the unit, allow a minimum of three inches of space around the unit for optimal 

ventilation. 

 

Preparing for Installation 

Before you begin the installation, be sure to review the Important Safety Instruction on page 3 of 

this manual and be aware of all safety and electrical codes which must be met in your area. 

AC Input of the inverter charger can be supplied from either a split-phase or a dual-input AC 

Source. See below to understand more about the unit before you start your installation. 

 

Input AC Source from Split-Phase: 

The split-phase AC source has 2 lines, 1 neutral and 1 ground. The two 120Vac lines are 180 

degree out of phase with each other with a total of 240Vac when measured from line to line. The 

voltage between each line to neutral is 120Vac.  

 

Input AC Source from Dual Input: 

The dual input has 2 line inputs, 1 neutral and 1 ground. The two 120Vac lines are in phase and 

must come from the same source.  

 

AC Loads: 

In Battery-Inverter mode, the unit’s AC Output L1 and L2 lines are connected together to provide 

120Vac on both lines.  

In Pass-Through mode, the AC source connected to the unit’s AC input is passed through to the 

AC Output (load). 

DANGER:

 Electrical Shock Hazard. 

Do not connect 240VAC load to the AC Output of the unit. 

 

AC Output Neutral Bonding: 

Each AC source must have its neutral conductor bonded to ground. 

When the Nature Power Inverter-Charger is running in Battery-Inverter mode, the internal 

neutral-to-ground bonding system is enabled. The unit will act as an AC source and will 

automatically connect the AC Output Neutral (N1 & N2) circuit to safety ground.  

When the unit is running in Pass-Through mode, the internal neutral-to-ground bonding system 

is disabled. The unit will not act as an AC source and the AC Output (N1 & N2) to safety ground 

is disconnected inside the unit. Therefore, the AC Input source that is connected to the Inverter-

Charger should have its own neutral-to-ground connection. If not, have an electrician look into 

bonding the AC source’s neutral to ground at your AC source. 

 

Reset button 

 

 

Power button 

 

 

Status LED 

Indicator 

 

Fan opening 

 

 

 

 

DC Input 

Te 

 

Ventilation 

 

DC Input 

Terminal - 

 

GND Stud 

 

Содержание 38330

Страница 1: ...3000W Pure Sine Inverter Charger 38330 Owner s Manual SINGLE COLOR Used for background colors other than Black or White White Used for black or dark grey background color ...

Страница 2: ...de Nature Power assumes no responsibility for errors or omissions Note as well that specifications and product functionality may change without notice Important Please be sure to read and save the entire manual before using your Nature Power Inverter Misuse may result in damage to the unit and or cause harm or serious injury Read manual in its entirety before using the unit and save manual for fut...

Страница 3: ...way from children Avoid moisture Never expose unit to snow water etc Unit provides 120 VAC treat the AC output the same as regular wall AC sockets at home DANGER Explosion hazard DO NOT use the unit in the vicinity of flammable fumes or gases such as propane tanks or large engines AVOID covering the ventilation openings Always operate unit in an open area Prolonged contact to high heat or freezing...

Страница 4: ... Page 4 Table of Contents 1 INTRODUCTION 5 2 PRODUCT DESCRIPTION 5 3 INSTALLATION 6 4 UNIT OPERATION 10 5 TROUBLESHOOTING 13 6 SPECIFICATIONS 15 7 WARRANTY 16 ...

Страница 5: ...multi stage charging capability to minimize charging time The Power Factor Corrected PFC input minimizes AC input current required for charging Optional Battery Temperature Sensor BTS is available and used to sense the battery temperature to correct charging voltage to ensure the battery is fully charged A Manual Equalization Mode is built in to improve the life and performance of flooded batterie...

Страница 6: ... line The voltage between each line to neutral is 120Vac Input AC Source from Dual Input The dual input has 2 line inputs 1 neutral and 1 ground The two 120Vac lines are in phase and must come from the same source AC Loads In Battery Inverter mode the unit s AC Output L1 and L2 lines are connected together to provide 120Vac on both lines In Pass Through mode the AC source connected to the unit s A...

Страница 7: ...gh the ground stud of the unit DC Fuse or Over Current Protective Device A DC rated fuse or a DC rated over current protective device connected along the DC positive line is required Based on the National Electrical Code requirement a fuse or circuit breaker with a minimum of 350 Adc is required Based on the size of your 12V Battery Bank determine the overall short circuit current rating of the ba...

Страница 8: ...n a separate well ventilated compartment Do not install the unit in any compartment containing flammable gases or liquids like gasoline or in the battery compartment where they may be explosive hydrogen gas from the batteries present The length and size of the DC cables will affect unit performance For indoor use the unit can be mounted in any direction except with the fan panel panel with fan ope...

Страница 9: ... to the battery negative terminal Make sure the DC Disconnect Switch is in the OFF position Connect one end of the positive DC input cable to the Inverter Charger DC positive terminal Connect the other end of the positive DC input cable to one of the terminals of the DC Disconnect Switch Connect a DC input cable between the other terminal of the DC Disconnect Switch and one side of the terminal of...

Страница 10: ...s Non Backup Mode Same as Auto Backup Mode but when there is a power failure of the utility or the AC input source is not available the inverter will not turn ON automatically You are required to manually turn ON the inverter This setting is the same as factory default but with Inverter set to OFF Understanding the Display Functions LED Indicator functions on unit display and remote display Status...

Страница 11: ...ting mode Understanding the Charger Functions Three Stage Charging The Three Stage Charging algorithm has a Bulk then Absorption and then Float sequence During the Bulk stage the battery accepts the maximum constant current from the charger In the Absorption stage the battery voltage is held to constant voltage and the charging will slowly reduce In Float stage the charger continuously produces vo...

Страница 12: ...arging Voltage Adjustment from 25 C normal setting Flooded and GEL type AGM type 25 C 0 027 V C 0 021 V C 25 C 0 V 0 V 25 C 0 027 V C 0 021 V C Note The charger will terminate battery charging when the BTS senses the battery temperature reaching 60 C It will not continuously make voltage adjustments when the battery temperature drops to below 0 C Understanding the Error Codes Error Code on Display...

Страница 13: ...er On Off Turns Power Inverter On Off SCR set 15 20 25 30 A Set AC Input Source Power Breaker Rating During by pass mode with high demand for AC power for the load the charger current is reduced automatically to prevent the tripping of the AC Source power breaker Power Save 0 5 10 15 20 50W Lowers power draw when low power loads are connected to inverter Battery Type AGM GEL Flooded Select battery...

Страница 14: ...n be restarted No AC output Fault LED is on 30A Circuit Breaker is tripped and check fault code Check load and reset the AC breaker and verify the error condition and make correction Condition Inverter setting is set to On AC source is not available No AC Output Battery Power LED is off Unit is turned Off Turn unit ON by following the instruction as in Section 4 No DC power to unit Battery voltage...

Страница 15: ...t L1 N1 30A AC Output Line 1 L1 N1 and Line 2 L2 N2 30A Remote Display Display Panel Port RJ45 socket LCD Display AC Input Output Voltage Current DC Input Output Voltage Current Battery Temperature Sensor Port BTS Port RJ45 socket Charger Charging Voltage Range 7 16 VDC Floated Voltage Range 13 45 13 8 VDC Charging Control 3 Stages Bulk Absorption Float Charger Current max 150A Charger Current Set...

Страница 16: ...o retail store After speaking to a customer service representative if products are deemed non working or malfunctioning the product may be returned to the purchasing store within 30 days of original purchase Any defective unit that is returned to manufacturer within 30 days of the date of purchase will be replaced free of charge If such a unit is returned more than 30 days but less than one year f...

Отзывы: