background image

 

   

Page 

16 

   

   

   

 

8.  WARRANTY 

One Year Limited Warranty 

The limited warranty program is the only one that applies to this unit, and it sets forth all the 

responsibilities of Nature Power. There is no other warranty, other than those described herein. 

Any implied warranty of merchantability of fitness for a particular purpose on this unit is limited in 

duration to the duration of this warranty.  

This unit is warranted, to the original purchaser only, to be free of defects in materials and 

workmanship for one year from the date of purchase without additional charge. The warranty 

does not extend to subsequent purchasers or users. 

Manufacturer will not be responsible for any amount of damage in excess of the retail purchase 

price of the unit under any circumstances. Incidental and consequential damages are specifically 

excluded from coverage under this warranty.  

This unit is not intended for commercial use. This warranty does not apply to damage to units 

from misuse or incorrect installation/connection. Misuse includes wiring or connecting to 

improper polarity power sources.  

 

RETURN/REPAIR POLICY: 

If you are experiencing any problems with your unit, please contact our customer service 

department at 

[email protected]

 or Phone 1-800-588-0590 before returning 

product to retail store. After speaking to a customer service representative, if products are 

deemed non-working or malfunctioning, the product may be returned to the purchasing store 

within 30 days of original purchase. Any defective unit that is returned to manufacturer within 30 

days of the date of purchase will be replaced free of charge.  

If such a unit is returned more than 30 days but less than one year from the purchase date, 

manufacturer will repair the unit or, at its option, replace it, free of charge. If the unit is repaired, 

new or reconditioned replacement parts may be used, at manufacturer’s option. A unit may be 

replaced with a new or reconditioned unit of the same or comparable design. The repaired or 

replaced unit will then be warranted under these terms for the remainder of the warranty period. 

The customer is responsible for the shipping charges on all returned items.  

 

LIMITATIONS: 

This warranty does not cover accessories, such as adapters and batteries, damage or defects 

result from normal wear and tear (including chips, scratches, abrasions, discoloration or fading 

due to usage or exposure to sunlight), accidents, damage during shipping to our service facility, 

alterations, unauthorized use or repair, neglect, misuse, abuse, failure to follow instructions for 

care and maintenance, fire and flood. 

If your problem is not covered by his warranty, call our Customer Service Department at                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                              

[email protected]

 or 1-800-588-0590 for general information if applicable. 

 

 

Содержание 38330

Страница 1: ...3000W Pure Sine Inverter Charger 38330 Owner s Manual SINGLE COLOR Used for background colors other than Black or White White Used for black or dark grey background color ...

Страница 2: ...de Nature Power assumes no responsibility for errors or omissions Note as well that specifications and product functionality may change without notice Important Please be sure to read and save the entire manual before using your Nature Power Inverter Misuse may result in damage to the unit and or cause harm or serious injury Read manual in its entirety before using the unit and save manual for fut...

Страница 3: ...way from children Avoid moisture Never expose unit to snow water etc Unit provides 120 VAC treat the AC output the same as regular wall AC sockets at home DANGER Explosion hazard DO NOT use the unit in the vicinity of flammable fumes or gases such as propane tanks or large engines AVOID covering the ventilation openings Always operate unit in an open area Prolonged contact to high heat or freezing...

Страница 4: ... Page 4 Table of Contents 1 INTRODUCTION 5 2 PRODUCT DESCRIPTION 5 3 INSTALLATION 6 4 UNIT OPERATION 10 5 TROUBLESHOOTING 13 6 SPECIFICATIONS 15 7 WARRANTY 16 ...

Страница 5: ...multi stage charging capability to minimize charging time The Power Factor Corrected PFC input minimizes AC input current required for charging Optional Battery Temperature Sensor BTS is available and used to sense the battery temperature to correct charging voltage to ensure the battery is fully charged A Manual Equalization Mode is built in to improve the life and performance of flooded batterie...

Страница 6: ... line The voltage between each line to neutral is 120Vac Input AC Source from Dual Input The dual input has 2 line inputs 1 neutral and 1 ground The two 120Vac lines are in phase and must come from the same source AC Loads In Battery Inverter mode the unit s AC Output L1 and L2 lines are connected together to provide 120Vac on both lines In Pass Through mode the AC source connected to the unit s A...

Страница 7: ...gh the ground stud of the unit DC Fuse or Over Current Protective Device A DC rated fuse or a DC rated over current protective device connected along the DC positive line is required Based on the National Electrical Code requirement a fuse or circuit breaker with a minimum of 350 Adc is required Based on the size of your 12V Battery Bank determine the overall short circuit current rating of the ba...

Страница 8: ...n a separate well ventilated compartment Do not install the unit in any compartment containing flammable gases or liquids like gasoline or in the battery compartment where they may be explosive hydrogen gas from the batteries present The length and size of the DC cables will affect unit performance For indoor use the unit can be mounted in any direction except with the fan panel panel with fan ope...

Страница 9: ... to the battery negative terminal Make sure the DC Disconnect Switch is in the OFF position Connect one end of the positive DC input cable to the Inverter Charger DC positive terminal Connect the other end of the positive DC input cable to one of the terminals of the DC Disconnect Switch Connect a DC input cable between the other terminal of the DC Disconnect Switch and one side of the terminal of...

Страница 10: ...s Non Backup Mode Same as Auto Backup Mode but when there is a power failure of the utility or the AC input source is not available the inverter will not turn ON automatically You are required to manually turn ON the inverter This setting is the same as factory default but with Inverter set to OFF Understanding the Display Functions LED Indicator functions on unit display and remote display Status...

Страница 11: ...ting mode Understanding the Charger Functions Three Stage Charging The Three Stage Charging algorithm has a Bulk then Absorption and then Float sequence During the Bulk stage the battery accepts the maximum constant current from the charger In the Absorption stage the battery voltage is held to constant voltage and the charging will slowly reduce In Float stage the charger continuously produces vo...

Страница 12: ...arging Voltage Adjustment from 25 C normal setting Flooded and GEL type AGM type 25 C 0 027 V C 0 021 V C 25 C 0 V 0 V 25 C 0 027 V C 0 021 V C Note The charger will terminate battery charging when the BTS senses the battery temperature reaching 60 C It will not continuously make voltage adjustments when the battery temperature drops to below 0 C Understanding the Error Codes Error Code on Display...

Страница 13: ...er On Off Turns Power Inverter On Off SCR set 15 20 25 30 A Set AC Input Source Power Breaker Rating During by pass mode with high demand for AC power for the load the charger current is reduced automatically to prevent the tripping of the AC Source power breaker Power Save 0 5 10 15 20 50W Lowers power draw when low power loads are connected to inverter Battery Type AGM GEL Flooded Select battery...

Страница 14: ...n be restarted No AC output Fault LED is on 30A Circuit Breaker is tripped and check fault code Check load and reset the AC breaker and verify the error condition and make correction Condition Inverter setting is set to On AC source is not available No AC Output Battery Power LED is off Unit is turned Off Turn unit ON by following the instruction as in Section 4 No DC power to unit Battery voltage...

Страница 15: ...t L1 N1 30A AC Output Line 1 L1 N1 and Line 2 L2 N2 30A Remote Display Display Panel Port RJ45 socket LCD Display AC Input Output Voltage Current DC Input Output Voltage Current Battery Temperature Sensor Port BTS Port RJ45 socket Charger Charging Voltage Range 7 16 VDC Floated Voltage Range 13 45 13 8 VDC Charging Control 3 Stages Bulk Absorption Float Charger Current max 150A Charger Current Set...

Страница 16: ...o retail store After speaking to a customer service representative if products are deemed non working or malfunctioning the product may be returned to the purchasing store within 30 days of original purchase Any defective unit that is returned to manufacturer within 30 days of the date of purchase will be replaced free of charge If such a unit is returned more than 30 days but less than one year f...

Отзывы: