7.  SPECIFICATIONS 

Note: Specifications are subject to change without notice. 

 

Specification 

Nature Power 3000W Pure Sine 

Inverter-Charger

 

Inverter

 

  AC Output Power 

3000W 

  AC Output Current 

25A 

  AC Surge Power (Peak) 

6000W (5 seconds) 

  AC Output Voltage/Frequency 

120 VAC / 60 Hz 

  AC Output Waveform 

True Sinewave (<5% THD) 

  Nominal DC Input Voltage 

12.5 VDC 

  No Load battery draw 

< 3.5 A nominal, <1A with load sense 

  DC Input Voltage Operating Range 

11.0 - 16.0 VDC 

  Under Voltage Alarm 

11.8 VDC 

  Under Voltage Alarm Recovery 

12.2 VDC 

  Under Voltage Shutdown  

10.5 VDC 

  Under Voltage Recovery 

11.5 VDC 

  Over Voltage Shutdown 

16.5 VDC 

AC Transfer Switch

 

   Transfer Time 

< 20 ms 

   Transfer Relay Rating 

30A 

   AC Input Source Current Setting (SCR set) 

15, 20, 25A, 30A 

   AC Input L1, N1  

30A 

   AC Output Line 1 (L1, N1) and Line 2 ( L2, N2) 

30A 

Remote Display

 

   Display Panel Port 

RJ45 socket 

   LCD Display 

AC Input / Output Voltage & Current 

DC Input / Output Voltage & Current 

Battery Temperature Sensor Port

 

   BTS Port 

RJ45 socket 

    

 

Charger

 

   Charging Voltage Range 

7 – 16 VDC 

   Floated Voltage Range 

13.45 – 13.8 VDC 

   Charging Control 

3 Stages (Bulk/Absorption/Float) 

   Charger Current (max) 

150A 

   Charger Current Setting 

60A – 150A 

   Equalization Voltage (Flooded battery setting) 

16.0 VDC 

   Equalization Current (Flooded battery setting) 

½ Bulk Current (min 30A, max 75A) 

   Efficiency 

            >80% 

Safety and Environmental

 

  Conformance 

Conforms to UL 458 

Certified to CSA C22.2 no. 107.1 

  Agency Markings 

cETLus 

  Operating Temperature 

0°C to 40°C (32°F to 104°F) 

  Storage Temperature 

-20°C to 60°C (-4°F to 140°F) 

  Relative Humidity 

5-90% noncondensing 

  Operating Altitude 

Up to 9,843ft (3000m) above sea level 

Weights and Dimensions

 

  Weights 

66 lb (30 kg) 

  Dimensions 

15.4 x 13.4 x 7.8” (392x340x197mm) 

 

Содержание 38330

Страница 1: ...3000W Pure Sine Inverter Charger 38330 Owner s Manual SINGLE COLOR Used for background colors other than Black or White White Used for black or dark grey background color ...

Страница 2: ...de Nature Power assumes no responsibility for errors or omissions Note as well that specifications and product functionality may change without notice Important Please be sure to read and save the entire manual before using your Nature Power Inverter Misuse may result in damage to the unit and or cause harm or serious injury Read manual in its entirety before using the unit and save manual for fut...

Страница 3: ...way from children Avoid moisture Never expose unit to snow water etc Unit provides 120 VAC treat the AC output the same as regular wall AC sockets at home DANGER Explosion hazard DO NOT use the unit in the vicinity of flammable fumes or gases such as propane tanks or large engines AVOID covering the ventilation openings Always operate unit in an open area Prolonged contact to high heat or freezing...

Страница 4: ... Page 4 Table of Contents 1 INTRODUCTION 5 2 PRODUCT DESCRIPTION 5 3 INSTALLATION 6 4 UNIT OPERATION 10 5 TROUBLESHOOTING 13 6 SPECIFICATIONS 15 7 WARRANTY 16 ...

Страница 5: ...multi stage charging capability to minimize charging time The Power Factor Corrected PFC input minimizes AC input current required for charging Optional Battery Temperature Sensor BTS is available and used to sense the battery temperature to correct charging voltage to ensure the battery is fully charged A Manual Equalization Mode is built in to improve the life and performance of flooded batterie...

Страница 6: ... line The voltage between each line to neutral is 120Vac Input AC Source from Dual Input The dual input has 2 line inputs 1 neutral and 1 ground The two 120Vac lines are in phase and must come from the same source AC Loads In Battery Inverter mode the unit s AC Output L1 and L2 lines are connected together to provide 120Vac on both lines In Pass Through mode the AC source connected to the unit s A...

Страница 7: ...gh the ground stud of the unit DC Fuse or Over Current Protective Device A DC rated fuse or a DC rated over current protective device connected along the DC positive line is required Based on the National Electrical Code requirement a fuse or circuit breaker with a minimum of 350 Adc is required Based on the size of your 12V Battery Bank determine the overall short circuit current rating of the ba...

Страница 8: ...n a separate well ventilated compartment Do not install the unit in any compartment containing flammable gases or liquids like gasoline or in the battery compartment where they may be explosive hydrogen gas from the batteries present The length and size of the DC cables will affect unit performance For indoor use the unit can be mounted in any direction except with the fan panel panel with fan ope...

Страница 9: ... to the battery negative terminal Make sure the DC Disconnect Switch is in the OFF position Connect one end of the positive DC input cable to the Inverter Charger DC positive terminal Connect the other end of the positive DC input cable to one of the terminals of the DC Disconnect Switch Connect a DC input cable between the other terminal of the DC Disconnect Switch and one side of the terminal of...

Страница 10: ...s Non Backup Mode Same as Auto Backup Mode but when there is a power failure of the utility or the AC input source is not available the inverter will not turn ON automatically You are required to manually turn ON the inverter This setting is the same as factory default but with Inverter set to OFF Understanding the Display Functions LED Indicator functions on unit display and remote display Status...

Страница 11: ...ting mode Understanding the Charger Functions Three Stage Charging The Three Stage Charging algorithm has a Bulk then Absorption and then Float sequence During the Bulk stage the battery accepts the maximum constant current from the charger In the Absorption stage the battery voltage is held to constant voltage and the charging will slowly reduce In Float stage the charger continuously produces vo...

Страница 12: ...arging Voltage Adjustment from 25 C normal setting Flooded and GEL type AGM type 25 C 0 027 V C 0 021 V C 25 C 0 V 0 V 25 C 0 027 V C 0 021 V C Note The charger will terminate battery charging when the BTS senses the battery temperature reaching 60 C It will not continuously make voltage adjustments when the battery temperature drops to below 0 C Understanding the Error Codes Error Code on Display...

Страница 13: ...er On Off Turns Power Inverter On Off SCR set 15 20 25 30 A Set AC Input Source Power Breaker Rating During by pass mode with high demand for AC power for the load the charger current is reduced automatically to prevent the tripping of the AC Source power breaker Power Save 0 5 10 15 20 50W Lowers power draw when low power loads are connected to inverter Battery Type AGM GEL Flooded Select battery...

Страница 14: ...n be restarted No AC output Fault LED is on 30A Circuit Breaker is tripped and check fault code Check load and reset the AC breaker and verify the error condition and make correction Condition Inverter setting is set to On AC source is not available No AC Output Battery Power LED is off Unit is turned Off Turn unit ON by following the instruction as in Section 4 No DC power to unit Battery voltage...

Страница 15: ...t L1 N1 30A AC Output Line 1 L1 N1 and Line 2 L2 N2 30A Remote Display Display Panel Port RJ45 socket LCD Display AC Input Output Voltage Current DC Input Output Voltage Current Battery Temperature Sensor Port BTS Port RJ45 socket Charger Charging Voltage Range 7 16 VDC Floated Voltage Range 13 45 13 8 VDC Charging Control 3 Stages Bulk Absorption Float Charger Current max 150A Charger Current Set...

Страница 16: ...o retail store After speaking to a customer service representative if products are deemed non working or malfunctioning the product may be returned to the purchasing store within 30 days of original purchase Any defective unit that is returned to manufacturer within 30 days of the date of purchase will be replaced free of charge If such a unit is returned more than 30 days but less than one year f...

Отзывы: