1.  INTRODUCTION 

Thank you for purchasing the Nature Power

 

Inverter 2000W with 55Amp Inverter Charger. With 

our state of the art, easy to use design, this product will offer you reliable service by providing AC 
power and 5V USB power for your home, cabin, boat, RV or Trailer and recharge your battery 
automatically when utility AC is available. The Nature Power

 

Inverter 2000W with 55Amp Inverter 

Charger can run many AC-powered appliances when you need AC power anywhere. The 5V USB 
power can charge many USB-powered devices. The multi-stage battery charger will charge 
different type of batteries. 
This manual will explain how to use this unit safely and effectively. Please read and follow these 
instructions and precautions carefully. 

IMPORTANT SAFETY INFORMATION 

This section contains important safety information for the Nature Power

 

Inverter 2000W with 

55Amp Inverter Charger. Please read ALL instructions before use. 
The Nature Power

 

Inverter 2000W with 55Amp Inverter Charger contains no user-serviceable 

parts. See Warranty section for how to handle product issues. 

WARNING: FIRE AND/OR CHEMICAL BURN HAZARD  

  Do not cover or obstruct any air vent openings and/or install in a zero-clearance compartment.  

WARNING: FAILURE TO FOLLOW THESE INSTRUCTIONS CAN RESULT IN 
DEATH OR SERIOUS INJURY

 

  When working with electrical equipment or lead acid batteries, have someone nearby in case of 

an emergency. 

  St

udy and follow all the battery manufacturer’s specific precautions when installing, using and 

servicing the battery connected to the inverter.  

  Wear eye protection and gloves. 

  Avoid touching your eyes while using this unit. 

  Keep fresh water and soap on hand in the event battery acid comes in contact with eyes. If this 

occurs, cleanse right away with soap and water for a minimum of 15 minutes and seek medical 
attention. 

  Batteries produce explosive gases. 

DO NOT 

smoke or have an open spark or fire near the 

system. 

  Keep unit away from moist or damp areas. 

  Avoid dropping any metal tool or object on the battery. Doing so could create a spark or short 

circuit which goes through the battery or another electrical tool that may create an explosion. 

 WARNING: Shock Hazard. Keep away from children!

 

  Avoid moisture. Never expose unit to snow, water etc. 

  Unit provides 120 Vac, treat the GFCI output socket the same as regular wall AC sockets at 

home. 

WARNING: Explosion hazard!

 

  DO NOT use the unit in the vicinity of flammable fumes or gases (such as propane tanks or 

large engines). 

  AVOID covering the ventilation openings. Always operate unit in an open area. 

  Prolonged contact to high heat or freezing temperatures will decrease the working life of the unit.  

FCC INFORMATION  

This equipment has been tested and found to comply with the limits for a Class B digital device, 
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection 
against harmful interference in a residential installation. This equipment generate, uses and can 
radiate radio frequency energy and, if not installed and used in accordance with the instructions, 
may cause harmful interference to radio communications. However, there is no guarantee that 
interference will not occur in a particular installation. If this equipment does cause harmful 
interference to radio or television reception, which can be determined by turning the equipment off 
and on, the user is encouraged to try to correct the interference by one or more of the following 
measures:  
•  Reorient or relocate the receiving antenna.  
•   Increase the separation between the equipment and the receiver.  
•  Connect the equipment into an outlet on a circuit different from that to which the receiver is 

Содержание 38326

Страница 1: ...Version 1 1 1 Inverter 2000W with 55Amp Inverter Charger 38326 Owner s Manual ...

Страница 2: ...een taken to ensure the accuracy of the contents of this guide Nature Power assumes no responsibility for errors or omissions Note as well that specifications and product functionality may change without notice Important Please be sure to read and save the entire manual before using your Nature Power Inverter Charger Misuse may result in damage to the unit and or cause harm or serious injury Read ...

Страница 3: ...Page 3 Table of Contents 1 INTRODUCTION 4 2 PRODUCT DESCRIPTION 5 3 INSTALLATION 5 4 UNIT OPERATION 9 5 TROUBLESHOOTING 11 6 SPECIFICATIONS 14 7 WARRANTY 15 ...

Страница 4: ...occurs cleanse right away with soap and water for a minimum of 15 minutes and seek medical attention Batteries produce explosive gases DO NOT smoke or have an open spark or fire near the system Keep unit away from moist or damp areas Avoid dropping any metal tool or object on the battery Doing so could create a spark or short circuit which goes through the battery or another electrical tool that m...

Страница 5: ...al safety wiring regulations and installation codes Failure to follow these instructions can damage the unit and could also result in personal injury or loss of life CAUTION Before beginning unit installation please consider the following The unit should be used or stored in an indoor area away from direct sunlight heat moisture or conductive contaminants When placing the unit allow a minimum of t...

Страница 6: ...nding Cable Use of low resistance wire is required for all the DC connections between the unit and the battery bank For 32326 use minimum 2 0 AWG wire with maximum cable length of 5 feet Important The unit is grounded through the ground stud of the unit located near the DC Input terminal For the grounding cable connected between the unit s chassis and the earth ground use a matching cable size as ...

Страница 7: ...the OFF position Connect one end of the positive DC input cable to the Power Inverter DC positive terminal Connect the other end of the positive DC input cable to one of the terminals of the Disconnect Switch Connect a DC input cable between the other terminal of the Disconnect Switch and one side of the terminal of the fuse holder Connect a DC input cable between the other terminal of the fuse ho...

Страница 8: ...is limited to 16 6A for 2000W model 32326 Remote Display Connection The Remote Display on the unit is detachable To install the remote to different location an optional 6 pin standard RJ12 cable not provided is required Remove the 2 screws at the front of the Display Panel and remove the small RJ12 cable Install the optional RJ12 standard cable to your desired location Please note polarity Connect...

Страница 9: ... Display LED Display Function Status Green solid Green Ful By Pass Mode Battery is fully charged Green flashing OFF bul By Pass Mode Battery charging in progress and is in BULK mode OFF abs By Pass Mode Battery charging in progress and is in ABSORPTION mode Amber solid Green 12 5 Battery Mode inverter is running display shows battery voltage in DC volts Amber 0 80 Battery Mode inverter is running ...

Страница 10: ... high Check battery setting E11 Battery bad Battery did not accept charge E12 Internal transfer switch temperature is high and shutdown occurs Reduce load and check if any ventilation of the unit is blocked AC Load on Inverter Although the Power Inverter can provide high surge power up to two times the rated output power some high surge loads like sump pumps heavy duty motors etc may still trigger...

Страница 11: ...5A 4A 55A 6A Battery Type and Voltage Setting Bulk Absorption Float FLo Flooded 14 4V 14 4V 13 5V GEL GEL 14 2V 14 2V 13 8V AG AGM 14 3V 14 3V 13 4V Fi Fixed 13 5 Vdc fixed voltage Battery Under Voltage Setting SdL Battery under voltage setting is set to LOW setting used for normal operation Under voltage alarm 11 0 Vdc Under voltage alarm recovery 11 3 Vdc Under voltage shutdown 10 5 Vdc Under vo...

Страница 12: ...ger current reduced to 5A 85 C 185 F Charger current recover back to set value Environment Temperature 60 C 140 F Charger current reduced to 5A 55 C 131 F Charger current recover back to set value Enter Function Menu for unit setting To enter unit Function Menu press and hold Power and Select button together for about 5 seconds until a beep is sounded When you are in Function Menu Press Power butt...

Страница 13: ...Page 13 ...

Страница 14: ...ns are subject to change without notices Specification 38326 Inverter AC Output Power 2000W AC Output Current 16 6A AC Surge Power Peak 4000W AC Output Voltage Frequency 120 VAC 60 Hz AC Output Waveform Sinewave 3 THD Nominal DC Input Voltage 12 5 VDC No Load battery draw 1 5 ADC DC Input Voltage operating range 10 5 15 5 VDC Under Voltage Alarm 11 0 12 1 VDC Under Voltage Alarm Recovery 11 3 12 3...

Страница 15: ... not apply to damage to units from misuse or incorrect installation connection Misuse includes wiring or connecting to improper polarity power sources If you are experiencing any problems with your unit please contact our customer service department at info naturepowerproducts com or Phone 1 800 588 0590 before returning product to retail store After speaking to a customer service representative i...