6. TROUBLESHOOTING
To troubleshoot the unit, please note the error code displayed on the main unit and review
“Understanding the Error Codes” in section 4.
Problem
Symptom
Solution
No output
voltage. And
Status LED is
off.
The unit is off
Turn unit ON by following the instruction in
Section 4 to turn unit ON
No power to unit
Check DC fuse, Disconnect switch (if
installed) and check if Branch breaker is
either blown or turned OFF
No AC output.
Status LED is
Green
GFCI is tripped
Check load and reset the GFCI
No Output.
Status LED is
in Amber
GFCI is tripped
Check error code on display
Check AC Load Sense setting
Check load and reset the GFCI
Verify the error condition and make
correction
AC Load connected must be below the AC
Load sense setting
7. SPECIFICATIONS
Note: Specifications are subject to change without notices.
Specification
38326
Inverter
AC Output Power
2000W
AC Output Current
16.6A
AC Surge Power (Peak)
4000W
AC Output Voltage/Frequency
120 VAC / 60 Hz
AC Output Waveform
Sinewave (<3% THD)
Nominal DC Input Voltage
12.5 VDC
No Load battery draw
< 1.5 ADC
DC Input Voltage operating range
10.5
– 15.5 VDC
Under Voltage Alarm
11.0/12.1 VDC
Under Voltage Alarm Recovery
11.3/12.3 VDC
Under Voltage Shutdown
10.5/11.8 VDC
Under Voltage Recovery
12.0/12.6 VDC
Over Voltage Shutdown
15.5 VDC
USB
USB Port
5V, 750 mA
AC Transfer Switch
Transfer Time
< 30 ms
Transfer Relay Rating
30A
AC Input Source Setting
15, 20, 30A
AC Output Port 1 (HW Connector)
30A
AC Output Port 2 (HW Connector, GFCI, CB)
20A
AC Output Port 3 (GFCI & CB)
20A
Display
Display Panel Port
RJ12
Inverter Mode
Input Voltage, Output Power
Charger Mode
Status & Battery voltage
Charger
Charging Voltage Range
13.5 -14.4 VDC
Float Voltage Range
13.4
– 13.8 VDC
Charger Current (max)
55 ADC
Charger Current Setting
5,15,35,55