background image

Plug the control valve into an 

approved GFI power outlet us-

ing the supplied electrical cord; 

operation in the service position 

begins automatically.   

Your MG-10 is set at the factory 

default settings noted below. 

You can either check or change 

the settings by follow ing these 

instructions. 

Note: 

Display will cycle every 5 to 

10 seconds between the Time and 

number of days until the next regen-

eration cycle. This is normal.

1. Enter 

Time of Day

 mode (TD on left side) by 

pressing either the 

Up

 or 

Down 

arrow, and con-

tinue until display reads 12:01PM. 

2. Press 

Extra Cycle 

button OR leave display idle 

for ten seconds and 

Time of Day

 mode will be 

exited.

3. While time reads 12:01PM 

press & hold

 

both 

the 

Up

 and 

Down

 

arrows until display changes to 

(DF GAL). You are now in programming mode. 

1. Display should read (DF  GAL)

DF = Display Format / GAL = Gallons

2. Display should read (VT  FLtr)

VT = Valve Type / FLtr = Filter 

3. Display should read (CT   tc)

CT = Control Type / tc = Time Clock

4. Display should read (NT---1) 

NT = Number of Tanks / 1 = One

5. Display should read (DO  4)  

DO = Day Override (days between regeneration) 

Note:

 Regeneration every 4 days is the maximum recommended interval. Your source 

water may require regeration cycles to be performed more often. 

6. Display should read (RT  3:00) 

RT = Regeneration Time / 3:00 = 3 AM 

Note:

 

This setting represents the time of day in which the regeneration cycle will occur. 

Adjust if desired. 

7. Display should read (BW  15)

BW = Backwash / 15 = Fifteen Minutes

8. Display should read (BD  0)

BD = Brine Draw / 0 = Zero Minutes

9. Display should read (RR  5) 

RR = Rapid Rinse / 5 = Five Minutes

Note: 

When Extra Cycle button is pressed, Programming Mode will be exited. 

Display will revert to normal operation. Adjust the time of day to your current local 

time using the 

Up

 or 

Down

 arrows. 

Programming is now complete.

For each step below, press the 

Up

 or 

Down

 arrow until the display 

matches the step’s image. 

Proceed to each next step by pressing the 

Extra Cycle

 button once. 

Programming Mode - General Instructions

Entering Programming Mode

Power Failure:

 

In the event of power failure, the control valve will continue to keep 

time for 48 hours. All programming is saved indefinitely. When power is restored, 

Data Display

 will flash indicating power interuption. 

Press any button

 and display 

will stop flashing.

Manual Regeneration:

 To manually regenerate filter, 

press & hold 

the 

Extra Cycle

 

button for 10 seconds. 

5

6

MG-10 Control Valve Master Programming

Отзывы: