Important Notes on Installation 

 

Water Testing

 — 

Because of variances in water quality, if your water source 

is a well, please contact Support at 1-800-428-9419 before installation. You 
should have your water tested by a certified water laboratory.

 

Water Shutoff 

— 

Naturally Filtered will not be held liable for damages, 

including any and all water damage caused by this product or its plumbing. 
It is recommended that the homeowner consider the use of an electronic 
water shut off system (such as WaterCop –

  http://www.watercop.com

). 

See 

Warning page 9.

 

Drainage

 —  

The MG-10 requires a drain or drain field (dependant on local 

plumbing code) for the unit to dispose of water during its regeneration cycle. 
The drain or drain field must be able to disburse a minimum of 5 GPM. 

 

Water Pressure 

— 

Water pressure should not exceed 100 psi. If your water 

pressure is close to 100 psi, you must have a plumber install a pressure 
regulator on your main line before the MG-10. 

Existing Plumbing 

 — 

The condition of the existing plumbing should be 

free from lead, lime, and iron buildup. Piping that is heavily built up with lead, 
lime, and/or iron should be replaced. All new plumbing should be performed 
in accordance with local plumbing codes. 

Electric Code 

— 

An uninterrupted alternating current 110V (AC), 60 Hz, 

supply is required. Unit must be installed to meet the current National Elec-
tric Code. A ground-fault-interrupt (GFI) outlet is recommended to protect 
your unit. 

Install Checklist 

- Before you Start

Parts Checklist

1. Bypass Valve
2. 1” Male NPT Adapter
3. O-ring Couplings (2)
4. Mesh Bag
5. Barbed Drain Elbow

4

Assembly

•  Rear of Housing

Drain Line Outlet
•  Elbow attaches here

Main Supply Connection
•  Water supply OUT 
•  Water supply IN

Step 1 - Barbed Drain Elbow

Install Barbed Drain Elbow into Drain 

Line Outlet (Teflon tape may be used). 

This step must be completed prior to 

connecting O-ring Couplings. 

Step 2 - O-ring Couplings

Install 

both

 O-ring Couplings 

to the Main Supply Connection 

channels (one on right or OUT 

channel shown here). 

Step 4 - Secure Complete Manifold

Add 1” Male NPT Adapter and 

secure to manifold by tightening 

metal locking clamps. 

Step 3 - Bypass Valve

Attach the Bypass Valve Assembly to 

the Control Valve over the O-ring Cou-

plings just installed and lock in place 

using the metal locking clamps.

Inlet & Outlet Bypass Valves Closed 

In this position your MG-10 is in 

full by-pass mode.

Inlet and Outlet Bypass Valves Open 

Here bypass valves are open. This 

is the normal service position for 

the MG-10.

Tap 

Water

IN

Filtered

Water 

OUT

Assembling Bypass Valve