background image

21

Guidance and Manuf

actur

er’

s Declar

ation

 

–IMMUNITY t

o pr

oximity fi

el

ds fr

om RF wir

el

ess communications equipmen

t

Immunity T

es

t

IE

C6

06

0

1 t

es

t l

ev

el

Compliance l

ev

el

Tes

 

fr

equency

Mod

ulation

Maximum power

Immunity  leve

l

Radiat

ed RF

IE

C 6

1000-4-3

3

85 MHz

**Pulse Mod

ulation: 1

8Hz

1.8 W

27 V

/m

27 V

/m

4

5

0 MHz

*FM +5Hz d

eviation: 1kHz sine

2 W

28 V

/m

28 V

/m

71

0 MHz

74

5 MHz

780 MHz

**Pulse Mod

ulation: 2

17Hz

0.2 W

9 V

/m

9 V

/m

81

0 MHz

87

0 MHz

93

0 MHz

**Pulse Mod

ulation: 1

8Hz

2 W

28 V

/m

28 V

/m

17

20 MHz

184

5 MHz

19

70 MHz

**Pulse Mod

ulation: 2

17Hz

2 W

28 V

/m

28 V

/m

24

5

0 MHz

**Pulse Mod

ulation: 2

17Hz

2 W

28 V

/m

28 V

/m

52

4

0 MHz

55

00 MHz

57

85 MHz

**Pulse Mod

ulation: 2

17Hz

0.2 W

9 V

/m

9 V

/m

No

te

* - As an al

ternativ

e t

o FM mod

ulation, 5

0 % pulse mod

ulation at 1

8 Hz may be used because whil

e it d

oes no

repr

esen

t actual mod

ulation, it woul

d be wors

t case. No

te

** - The carrier shall be mod

ulat

ed using a 5

0 % d

uty cycl

squar

e wa

ve signal.

Содержание NCTG3

Страница 1: ...Instructions For Use NC THERMOMETER GEN3 Model number NCTG3...

Страница 2: ...r is being imported under FDA Enforcement Policy for Clinical Electronic Thermometers During the Coronavirus Disease 2019 Public Health Emergency This device meets performance requirements but is not...

Страница 3: ...3 Contents Introduction 4 Warnings And Cautions 6 Operating Your Thermometer 9 Maintenance 14...

Страница 4: ...nk you for purchasing the NC Thermometer Gen3 Please read these instructions carefully to ensure proper use and safe operation of your thermometer If you have any questions or comments about the therm...

Страница 5: ...Thermometer key parts Front Tip Wand History button Display Battery hatch NFC zone symbol Plastic tab Power button Back Settings button Tip is the part of the thermometer that is applied to the mouth...

Страница 6: ...ycles application IFU for information regarding use of the app This product is not intended to diagnose or treat any health problem or disease and should not be used as a substitute for the consultati...

Страница 7: ...it could result in improper operation If such use is necessary this equipment and the other equipment should be observed to verify that they are operating normally Use of accessories transducers and...

Страница 8: ...at help naturalcycles com Parts of the NC Thermometer Gen3 are not to be serviced or maintained while in use with the patient The patient is the intended operator The NC Thermometer Gen3 is a continu...

Страница 9: ...to the Natural Cycles app on their smartphone Before using the thermometer for the first time pull the plastic tab sticking out of the battery hatch to activate the battery To Set Up Your Thermometer...

Страница 10: ...ll confirm the switch to Fahrenheit or Celsius You can change thermometer settings in the app as well History Mode The thermometer includes a recall of the past ten temperatures taken Press the histor...

Страница 11: ...tton to turn the thermometer off or the thermometer will shut off automatically Troubleshooting Error Codes Performance may be affected should one or more of the following occur Operation outside stat...

Страница 12: ...ral Use section Temperature too high try again Starting temperature value is above 104 F 40 C or final temperature value is too high above 107 6 F 42 0 C Try measuring the temperature again Make sure...

Страница 13: ...ted Change the battery as described in the section Replacing The Battery Measuring error User does not take a stable measurement moving thermometer around mouth taking thermometer in and out of mouth...

Страница 14: ...ive case when not in use Do not store the thermometer where it will be exposed to direct sunlight dust or humidity Avoid extreme temperatures Do not attempt to disassemble the thermometer Clean the th...

Страница 15: ...tes if device left at rest 3 minutes if shaking the device in the air Measurement Time 40 seconds nominally Accuracy 0 1 C 0 2 F within measurement range Operating Temperature 15 40 C 59 104 F Storage...

Страница 16: ...erence that may cause undesired operation The equipment is suitable for use in domestic establishments and is tested to CISPR emissions Class B Group 1 as well as home healthcare immunity criteria fou...

Страница 17: ...llation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the inte...

Страница 18: ...chase date must be submitted The warranty will not apply in cases of Normal wear and tear Incorrect use e g overloading of the appliance use of non approved accessories Use of force damage caused by e...

Страница 19: ...Declaration electromagnetic emissions Emissions test Compliance RF emissions CISPR 11 Group 1 RF emissions CISPR 11 Class B Harmonic emissions IEC 61000 3 2 Not applicable Voltage fluctuations flicker...

Страница 20: ...al fast transient burst IEC 61000 4 4 Not applicable Not applicable Voltage dips short interruptions and voltage variations on power supply input lines IEC 61000 4 11 Not applicable Not applicable Pow...

Страница 21: ...710 MHz 745 MHz 780 MHz Pulse Modulation 217Hz 0 2 W 9 V m 9 V m 810 MHz 870 MHz 930 MHz Pulse Modulation 18Hz 2 W 28 V m 28 V m 1720 MHz 1845 MHz 1970 MHz Pulse Modulation 217Hz 2 W 28 V m 28 V m 245...

Страница 22: ...do not belong in household waste They must be disposed of at appropriate collection and disposal points Consult the instructions for use Dust tight Protected against splashing water Degree of protect...

Страница 23: ...ss of the Manufacturer No 100 Dongfu West Road Haicang District Xiamen Fujian China Contact Information http www intretech com 86 0 592 5797666 Device Name NC Thermometer Gen 3 Date of publication Feb...

Страница 24: ......