Troubleshooting Guide
NCC7222-07 R2- 111207
18
Cause
Action
1. Are Cold and Hot sensors (thermistors) in the correct position?
1. Check wiring diagram, remove, and reinsert. CAUTION - unplug
ION before any contact with Control Board.
2. On Models produced after September 1 … can you hear
a single initialization beep when ION is first plugged in?
2. If YES, then double check sensor wires and replace sensors
as needed.
If NO, then replace Control Board – programming error or defect
on Control Board (perhaps, shipping damage) is preventing
Control Board from initialization.
Problem: Steady Orange lights (never goes to blinking Orange lights)
IMPORTANT – on software rev level prior to L (Sept. 2007), a hot or cold sensor unplugged (or not completely
connected) will cause this condition. During shipping, the sensor connections can become unstable and may require
careful removal (straight back) and reinsertion onto the Control Board (see wiring diagram). CAUTION – unplug ION
before any contact with Control Board.
Содержание ION pure refreshment
Страница 1: ...NCC7222 07 R2 111207 TECHNICAL SERVICE MANUAL...
Страница 22: ...Frame Assembly NCC7222 07 R2 111207 21...
Страница 23: ...Display Valve Assembly Models 903 904 only NCC7222 07 R2 111207 22 for Models 903 904 only...
Страница 24: ...NCC7222 07 R2 111207 Filter Manifold Assembly 23...
Страница 25: ...Front Panel Assembly NCC7222 07 R2 111207 24...
Страница 26: ...Dispensing Assembly 901 NCC7222 07 R2 111207 25...
Страница 27: ...Dispensing Assembly 902 NCC7222 07 R2 111207 26...
Страница 28: ...Dispensing Assembly 903 NCC7222 07 R2 111207 27...
Страница 29: ...Dispensing Assembly 904 NCC7222 07 R2 111207 28...
Страница 30: ...Ice Bank Assembly NCC7222 07 R2 111207 29...
Страница 31: ...Final Assembly NCC7222 07 R2 111207 30...