Troubleshooting Guide
NCC7222-07 R2- 111207
16
Cause
Action
1. Loose connection behind Front Panel at Display Board
1. Reconnect or replace as needed.
2. ION in SleepMode
2. In very low light, after 5 minutes, ION goes into SleepMode
(default setting) unless programmed OFF (see Owners Manual,
programming section).
Problem: Blue LED not ON
IMPORTANT – SleepMode is an energy saving feature that is programmed into the Control Board. A photo sensor
behind the LED3 on Front Panel allows software to turn the compressor OFF when room is dark.
Check the location carefully… if room light is turned ON and OFF frequently during the day, this will be a problem for
the cooling system. See Owners Manual, programming section, and program the SleepMode feature to be OFF.
When SleepMode is ON, compressor is OFF after room is dark for 5 minutes; hot tank drops to 135F. When any
button is pressed, OR in light room after 5 minutes, SleepMode cycle ends, and hot tank and compressor are both
ON as needed to reach temperature.
Содержание ION pure refreshment
Страница 1: ...NCC7222 07 R2 111207 TECHNICAL SERVICE MANUAL...
Страница 22: ...Frame Assembly NCC7222 07 R2 111207 21...
Страница 23: ...Display Valve Assembly Models 903 904 only NCC7222 07 R2 111207 22 for Models 903 904 only...
Страница 24: ...NCC7222 07 R2 111207 Filter Manifold Assembly 23...
Страница 25: ...Front Panel Assembly NCC7222 07 R2 111207 24...
Страница 26: ...Dispensing Assembly 901 NCC7222 07 R2 111207 25...
Страница 27: ...Dispensing Assembly 902 NCC7222 07 R2 111207 26...
Страница 28: ...Dispensing Assembly 903 NCC7222 07 R2 111207 27...
Страница 29: ...Dispensing Assembly 904 NCC7222 07 R2 111207 28...
Страница 30: ...Ice Bank Assembly NCC7222 07 R2 111207 29...
Страница 31: ...Final Assembly NCC7222 07 R2 111207 30...