Chapter 3
Configuration and Installation
©
National Instruments Corporation
3-5
VXI/VMEpc 600 Series User Manual
Table 3-1 lists the factory-default settings and options for the onboard
jumpers and switches.
Note
Please do not adjust the jumpers on any jumper blocks not listed in Table 3-1
unless directed by National Instruments support.
Table 3-1.
VXI/VMEpc 600 Series Hardware Default Settings
Jumper
Default Setting
Optional Setting
W1
Enable MITE
self-configuration
Disable MITE
self-configuration
W2
No termination on
external trigger input
Terminate external trigger
input to 50
Ω
W3
Supply SCSI termination
Disable SCSI termination
W4
Receive CLK10 input
from SMB
Source CLK10 output to
SMB
W5
No termination on CLK10
input
Terminate CLK10 input
to 50
Ω
W6
Source CLK10 from
onboard oscillator
Source CLK10 from SMB
W7
Non-inverted CLK10
output
Inverted CLK10 output
W9
MITE user configuration
MITE factory
configuration
W11
Enable automatic slot
detection
Force System Controller;
Force Non-System Cont.
W20
Normal CMOS operation
Clear CMOS