Chapter 3
Configuration and Installation
©
National Instruments Corporation
3-13
VXI/VMEpc 600 Series User Manual
2.
Power-on the VXI/VMEpc-650. The screen should briefly appear, and
then go black.
3.
Power-off the VXI/VMEpc-650.
4.
Remove the jumper as shown in Figure 3-13a to restore normal
operation.
Figure 3-13.
System CMOS
Installing the VXI/VMEpc 600 Series
This section contains general installation instructions for the
VXI/VMEpc 600 Series. Consult your VXI/VMEbus mainframe user
manual or technical reference manual for specific instructions and
warnings.
1.
Plug in your mainframe before installing the VXI/VMEpc 600 Series.
The power cord grounds the mainframe and protects it from electrical
damage while you are installing the module.
Warning
To protect both yourself and the mainframe from electrical hazards,
the mainframe should remain off until you are finished installing the
VXI/VMEpc 600 Series module.
2.
Remove or open any doors or covers blocking access to the mainframe
slots.
Caution
If the VXI/VMEpc 600 Series is not configured for automatic System Controller
detection, be certain that the slot you select in your VXI/VMEbus mainframe
matches the VXI/VMEpc 600 Series configuration as either a System Controller
device or a Non-System Controller device. Installing the VXI/VMEpc 600 Series
into a slot that does not correspond with the jumper setting can damage the
VXI/VMEpc 600 Series, the VXI/VMEbus backplane, or both.
3.
Insert the VXI/VMEpc 600 Series in the slot you have selected by
aligning the top and bottom of the module with the card-edge guides
inside the mainframe. Slowly push the VXI/VMEpc 600 Series
straight into the slot until its plug connectors are resting on the
a. Normal Operation
(Default)
W19
W20
b. Clear CMOS
Contents
W19
W20
!